CRIMP DATA ANALYZER
CDA10
REV.01
37
3.3.3
FORCE CELL SENSOR
The piezoelectric sensor
converts the force applied by
the press in an electrical
signal which is read and
monitored by the control
unit.
On model TT and P107
presses, the cell sensor (C)
and the spacer plate (B) are
placed between the support
(A), screwed to the press
slide, and the "T"-connector
(E).
The sensor cable (D) is fixed
with clips to the slide and to
the press frame.
On model P040 and P080 presses, the sensor (C) is
placed between the slide and the shank connection.
The sensor cable (D) is fixed with clips to the press
frame.
Only on these press models, an amplifier must be
inserted between the sensor and the control unit.
Summary of Contents for CDA10
Page 2: ......
Page 3: ......
Page 11: ...CRIMP DATA ANALYZER CDA10 REV 01 9...
Page 20: ...CRIMP DATA ANALYZER CDA10 REV 01 18...
Page 22: ...CRIMP DATA ANALYZER CDA10 REV 01 20...
Page 31: ...CRIMP DATA ANALYZER CDA10 REV 01 29...
Page 33: ...CRIMP DATA ANALYZER CDA10 REV 01 31...
Page 36: ...CRIMP DATA ANALYZER CDA10 REV 01 34...
Page 41: ...CRIMP DATA ANALYZER CDA10 REV 01 39...
Page 43: ...CRIMP DATA ANALYZER CDA10 REV 01 41...
Page 48: ...CRIMP DATA ANALYZER CDA10 REV 01 46...
Page 50: ...CRIMP DATA ANALYZER CDA10 REV 01 48...
Page 65: ...CRIMP DATA ANALYZER CDA10 REV 01 63...
Page 66: ...CRIMP DATA ANALYZER CDA10 REV 01 64...
Page 67: ...CRIMP DATA ANALYZER CDA10 REV 01 65...
Page 69: ...CRIMP DATA ANALYZER CDA10 REV 01 67...
Page 95: ...CRIMP DATA ANALYZER CDA10 REV 01 93...
Page 99: ...CRIMP DATA ANALYZER CDA10 REV 01 97...
Page 101: ...CRIMP DATA ANALYZER CDA10 REV 01 99...
Page 113: ...CRIMP DATA ANALYZER CDA10 REV 01 111 MAINTENANCE LOG DATE OPERATOR DESCRIPTION OF INTERVENTION...
Page 115: ...CRIMP DATA ANALYZER CDA10 REV 01 113...
Page 117: ...CRIMP DATA ANALYZER CDA10 REV 01 115...
Page 119: ...CRIMP DATA ANALYZER CDA10 REV 01 117 9 1 MACHINE LAYOUT...