93924 – September 2015
60-J Diesel
Operating Instructions & Pre-Operation Function Tests
Platform Operations Test
Emergency Stop
• Press the EMERGENCY STOP switch at any time to stop all machine
functions.
• Turn switch
clockwise
to reset.
• Depress the EMERGENCY STOP switch whenever the machine is not in
operation. Turn switch
clockwise
to reset.
Activation of the EMERGENCY STOP switch will apply brakes immediately.
This will cause sudden platform movement as the machine comes to an abrupt stop.
Brace yourself and secure objects on the platform during operation of machine.
Select PLATFORM Operation
•
Base Controls:
Turn the selector switch to PLATFORM.
Operate from Platform
• Enter the platform through one of the personnel entry gates. Close and secure
the entry.
• Press the Start/Stop switch UP to start. Release the switch when the engine
starts.
• Press the Horn Button to verify proper operation.