Page 16
93924 – September 2015
60-J Diesel
Operating Instructions & Pre-Operation Function Tests
Starting Engine from Base Controls
Be sure that the upper and lower EMERGENCY STOP Switches are reset.
•
Lower Control Box:
Turn Key Switch to CHASSIS.
• Move the Start/Stop switch to the right to start. Release the switch when the engine
starts.
•
Cold Start:
Move and hold the Glow Switch up as indicated in the Preheat table.
• With the Glow switch held up, press and hold the Start/Stop switch to the right until
the engine starts.
• Release both switches once the engine starts.
• To protect the starter motor, power will cut off to the starter circuit when the starter
motor has run continuously for 15 seconds without starting the engine. The Starter
Circuit Cutout indicator light will turn on and power to the starter circuit will cut out
for 30 seconds.
ART_4714
ART_4722
ART_4723
Preheat Table
Ambient Temperature
Preheat Time
Above 10°C
5 Seconds
10°C to –5°C
10 Seconds
Below –5°C
20 Seconds
20 Seconds = Limit of Continuous Use
ART_4724