Page 70
45-J Desel - Servce & Parts Manual
January 2022
Secton 18 - Mechancal Components
Note:
Load Cells are used on any machine equipped with the optional Overload Sensing System.
The Spacer Plate is used only if the optional Overload Sensing System is not present.
Assembly
Assembly is the reverse of disassembly.
Examine all pins for signs of wear, surface imperfections, cracks or gray dust in the pivot area.
Replace if any of the above conditions exist.
Tighten all fasteners to proper torque as shown below. Refer to Section 4 - Torque Specifications of
this manual for torque specifications of fasteners not listed below.
Location
Torque
Platform Rotator to Spacer/Load Cell
55 Lb-ft
75 N-m
Spacer/Load Cell to Platform Mount Weldment
95 Lb-ft
129 N-m
Platform Rotator Through Bolt & Nut
420/450 Lb-ft
569/610 N-m