Continuity Checks
Selector Switch – On-Off
Disconnect wires.
Connect the first probe of the ohm meter to Common
terminal.
Connect the second probe to any Normally Open terminal.
With switch OFF (open) there should be an open circuit.
With the switch ON (closed) there should be continuity.
Repeat for each Normally Open terminal.
•
•
•
•
•
•
Common
Normally
Open
Normally
Closed
ART_3153
Toggle Switch – On-Off
Disconnect wires.
Connect the first probe of the ohm meter to Common
terminal.
Connect the second probe to Normally Open terminal.
With the switch turned OFF there should be an open circuit.
With the switch turned ON there should be continuity.
•
•
•
•
•
Common
Normally Open
Not Used
Common
Normally Open
Not Used
ART_2562
Toggle Switch – 1-Pole 2-Position
Disconnect wires.
Connect the first probe of the ohm meter to Common
terminal.
Connect the second probe to top Normally Open terminal.
With toggle DOWN there should be no reading.
With the toggle UP there should be a low resistance.
Move the second probe to bottom Normally Open terminal.
With toggle UP there should be an open circuit.
With the toggle DOWN there should be continuity.
•
•
•
•
•
•
•
•
Common
Normally Open
Normally Open
Common
Normally Open
Normally Open
ART_2563
Toggle Switch – 1-Pole 3-Position
Disconnect wires.
Connect the first probe of the ohm meter to Common
terminal.
Connect the second probe of ohm meter to Top terminal.
With the toggle UP or MIDDLE there should be continuity.
Move second probe to Bottom terminal.
With the toggle DOWN or MIDDLE there should be
continuity.
Connect first probe of ohm meter to Top terminal.
Connect second probe of ohm meter to Bottom terminal.
With toggle in ANY POSITION there should be an open
circuit reading.
•
•
•
•
•
•
•
•
•
Common
Top
Bottom
Common
Top
Bottom
ART_3152