![Measuretek PSE User'S & Technical Manual Download Page 32](http://html.mh-extra.com/html/measuretek/pse/pse_users-and-technical-manual_1758423032.webp)
PSE
.
30
.
3
0= eeprom OK
0=calibration ok
0=initial zero ok
0=battery ok
1= eeprom error
1=calibration error
1=initial zero error
1=low battery
4
always 1
always 1
always 1
always 1
5
always 1
always 1
always 1
always 1
6
always 0
always 1
always 1
always 0
7
parity
parity
parity
parity
6.
Communication Details when
USER-COM1/2-LAYOUT
is set to
SINGLE
:
a.
Commands and response
i.
Command:
W<CR>
(57h 0dh), request current reading
Response:
①
<LF>^^^^^^^^U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---over capacity
②
<LF>_ _ _ _ _ _ _ _ U1U2 U3 U4U5<CR><LF> H1H2H3 H4<CR><ETX>---under
capacity
③
<LF> - - - - - - - - U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---zero-point error
Note:
U
1
U
2
U
3
U
4
U
5
is 1,2,3 or 5 bytes according to current unit: %, kg, lb, pcs, lb:oz
④
<LF><P>W
1
W
2
W
3
W
4
W
5
<DP>W
6
U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>---normal data
Note:
(1) The decimal point position is determined by
CONFIG-PRIM.D
(2) If current unit is ¡ lb:oz¡ , the format will be similar with following:
<LF><P>W
1
W
2
W
3
lb<SP>
W
4
W
5
<DP>W
6
oz
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>
ii.
Command:
S<CR>
(53h 0dh) , request current status
Response: <LF> H
1
H
2
H
3
H
4
<CR><ETX>
iii.
Command:
Z<CR>
(5ah 0dh)
Response: Zero function is activated (simulate
ZERO
key) and it returns to current scale
status.
<LF> H
1
H
2
H
3
H
4
<CR><ETX>
If ZERO function cannot be activated, it will return to current scale status.
iv.
Command:
T<CR>
(54h 0dh)
Response: TARE function is activated (simulate
TARE
key), and then returns scale status.
<LF> H
1
H
2
H
3
H
4
<CR><ETX>
If TARE function cannot be activated, it will return to current scale status.
v.
Command:
U<CR>
(55h 0dh)
Response: Changes units of measure (simulate
UNIT
key) and return scale status with new
units,
The new measure unit should be allowed to use
<LF> U
1
U
2
U
3
U
4
U
5
<CR><LF> H
1
H
2
H
3
H
4
<CR><ETX>
vi.
Command:
L<CR>
(4ch 0dh)
Response: If Hold function can be activated, it will enable/disable hold function (simulate
HOLD
key), and returns scale status.
<LF> H
1
H
2
H
3
H
4
<CR><ETX>