![Measuretek PSE User'S & Technical Manual Download Page 27](http://html.mh-extra.com/html/measuretek/pse/pse_users-and-technical-manual_1758423027.webp)
PSE
.
25
.
calculated unit-percentage-weight is less than 0.5d, the indicator will display
Pct.Er
and return back to percent weighing mode.
b.
Using the weigh samples weight when percentage is known
i.
Press the
UNIT/DATA
key, when
InP.Pct
is shown, use
key to select
SPL.Pct
,
then press the
TARE/PRESET
key to weigh samples (when the percentage is
known), and to calculate the piece weight. Press
ZERO/ON/OFF
key to exit and return to
percent weighing mode.
ii.
When
SPL.Lo
is shown, remove all samples from the scale and press the
TARE/PRESET
key to confirm. Before the scale is stable,
SPL.Lo
will be flashed. When the scale
becomes stable, continue to the next step. Press the
ZERO/ON/OFF
key to exit and
return to percent weighing mode.
iii.
When
SPL.Hi
is shown, place samples (when the percentage is known) onto the scale.
Press the
TARE/PRESET
key to confirm reading weight. Before the scale is stable,
SPL.Hi
will be flashed. When the scale becomes stable, continue to the next step. Press
the
ZERO/ON/OFF
key to exit and return to percent weighing mode.
iv.
After
INP.PCT
is displayed quickly, the previously entered percent will be shown (the
default value is
000000
, and the position of decimal point is determined by
CONFIG-FUNC-PERCEN
setting, use key to input the percentage of
samples and press the
TARE/PRESET
key to confirm. If the calculated
unit-percentage-weight is less than 0.5d, the indicator will display
Pct.Er
and return to
percent weighing mode, otherwise, after the reasonable unit-percentage-weight is
calculated, the scale will return to percent weighing mode. The calculated
unit-percentage-weight can be saved when the scale has been powered off and it can be
used the next time the scale is powered on.
Check Percent (percentage compare) in Percent weighing mode
To make the percentage compare function available,
CONFIG-FUNC-COMPAR
menu item should be set
to
YES
, and high and low limitation of percentage should be set according to following steps:
1.
In percent weighing mode, press the
UNIT/DATA
key for more than 4 seconds to input compare
data of high and low.
2.
After
HIGH
is displayed,
000000
will then be displayed, use
key to input
high percentage number and press the
TARE/PRESET
key to confirm. Announciator of
HI
will
then be shown. Press the
ZERO/ON/OFF
key to exit and return to percent weighing mode.
3.
After
Low
is displayed quickly,
000000
will then be displayed, use
key to input
low percentage number and press the
TARE/PRESET
key to confirm. Announciator of
LO
will be
shown in this step. Press
ZERO/ON/OFF
key to exit and return to counting mode.