INNENSTATION

INDOOR STATION
BOÎTIER INTÉRIEUR
BINNENSTATION

Note

: In order to prevent a door opening by tampering of the outdoor 

station, we recommend the installation of the separately available 
security door opener module SDO-10, which is mounted in the service 
entrance box. The SDO-10 is also suitable for motor locking systems and 
offers several adjustable door opening times and an 
auto-door-open function.

Connecting the power supply

The power supply can be connected to either the indoor or the outdoor 
station. Separate spring clips are present for this purpose.

It is also possible to connect the power supply directly to the signal line 
e.g. from the fuse box to the outdoor and indoor units. The power supply 
unit then needs to be connection with the ground (GND) and +15V.
Open power supply unit can supply up to 8 units with power.

Connecting a floor button

Any floor button that is present (normal closing contact) is connected in 
parallel to the terminals ‘audio’ and ‘GND’. 
On the 2- and 3-family versions please note that the correct audio line 
is used (Audio1 and GND for family 1, Audio2 and GND for family 2 and 
Audio3 and GND for family 3).

Note

: If a floor button is connected then an unchangeable ring tone 

is played when the floor button is activated. This ring tone is fixed 
and is not included in the ‘normal’ tones/melodies to make it easy to 
differentiate.

Connecting the wireless expansion model VTX-BELL

The VTX-BELL can be used to send the bell signal wirelessly to the 
receiver in the BELL series (currently BELL 200 RX, BELL 210 USB and 
BELL 220 RX). The wireless module will be attached to the 3-pole plug 
inside the indoor station (Figures C). For more information please see 
the VTX-BELL instructions.

The plug for the VTX-Bell transmitter is located on the front of the main 
PCB. To install the transmitter, unscrew the PCB from the housing. Remo-
ve the eight screws which connect the PCB to the housing (Fig. C No. 1).
Then remove the PCB and turn it over. A 3-pin plug is located at the 
top of the PCB. It is labelled with Signal, GND and VCC. Attach the 
transmitter connecting cable to the plug so that yellow is connected to 
Signal, black to GND and red to VCC. Turn the PCB over again and route 
the cable to the back of the PCB as shown in Fig. 2 B. Make sure that 
the cable is not squeezed at any point. Screw the PCB back on using the 
eight screws.
Now connect the transmitter to the cable and fix it in place with a piece 
of adhesive tape.

Alternatively, the VTX-Bell can also be attached directly to the plug, 
however the button for selecting the bell tone on the VTX-Bell will no 
longer be easily accessible.

POSSIBLE SETTINGS ON THE OUTDOOR STATION

The outdoor station has the following possibilities of adjusting the 
system to your personal circumstances:

Volume on the outdoor station

The potentiometer (Figure A ‚Volume / Lautstärke‘) is used to set 
the speaking volume on the outdoor station. For full volume turn the 
potentiometer carefully in a clockwise connection until it stops and turn 
it back a little. Turning the potentiometer in an anti-clockwise direction 
reduces the volume.

ID code

If several outdoor stations are used in parallel (e.g. on the gate and 
on the house), the DIP switch is used to set the ID code (Figure A, 
‚ID-CODE‘). 

ID1 = Switch 1 ‘on’, Switch 2 ‘on’
ID2 = Switch 1 ‘on’, Switch 2 ‘off’
ID3 = Switch 1 ‘off’, Switch 2 ‘on’

Door opener time

The DIP switch (Figure A, ‚Door opener time‘) is used to set how long 
the door opener should be activated for. The possible settings are 1 
second or 5 seconds. 5 seconds is the factory setting and works for 
most standard door openers.

Switch  ‘off’ corresponds to an opening time of 1 second.
Switch  ‘on’ corresponds to an opening time of 5 seconds.

POSSIBLE SETTINGS ON THE INDOOR STATION

The following settings are possible on the indoor station to adjust the 
system to your personal circumstances:

Ring tone volume

The potentiometer (Figure C ‘Bell Volume‘’) is used to set the ring/
volume on the indoor station. For full volume turn the potentiometer 
carefully in a clockwise connection until it stops. Turning the potentio-
meter in an anti-clockwise direction reduces the volume.

VISTUS AD-400_I-Manual_210x240_Fin8-1.indd   16

13.06.13   15:30

Summary of Contents for VISTUS AD ALU-410

Page 1: ...VISTUS AD 4010 VISTUS AD 4020 VISTUS AD 4030 VISTUS AD 400 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI GEBRUIKSAANWIJZING VISTUS AD 400_I Manual_210x240_Fin8 1 indd 1 13 06 13 15 30...

Page 2: ...B AFBEELDING B A B VISTUS AD DEUTSCH DE 2 2 3 7 6 3 4 5 13 12 11 14 15 AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION 6 4 5 V...

Page 3: ...C DIAGRAM C ILLUSTRATION C AFBEELDING C C DEUTSCH VISTUS AD 3 INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 3 13 06 13...

Page 4: ...hrt werden MONTAGE DER AU ENSTATION Die T rsprechstelle ist f r eine Aufputz Montage vorgesehen Vorbereitung Achten Sie beim Abnehmen des Frontcovers darauf dass die Namens schilder nicht herausfallen...

Page 5: ...ingeltaster Anschlussklemme 3 f r den oberen Klingeltaster 1 Entfernen Sie die zwei Schrauben um das Geh use der Au ensta tion ffnen zu k nnen Das Geh use ist zus tzlich noch mit Nasen und Nuten ausge...

Page 6: ...nenstation gesteckt Abb C N here Informationen entnehmen Sie bitte der Anleitung des VTX BELL Der Stecker f r den Sender VTX Bell befindet sich auf der Vorderseite der Hauptplatine PCB Front Um den Se...

Page 7: ...rs nlichen Gegebenheiten anzupassen Klingeltonlautst rke Mit dem Potentiometer Abb C Bell Volume wird die Klingellautst rke der Innenstation eingestellt F r volle Lautst rke drehen Sie das Potentio me...

Page 8: ...nigen vom Netz trennen Stecker ziehen Die Oberfl che des Geh uses kann mit einem mit Seifenlauge angefeuchtetem weichen Tuch gereinigt werden Verwenden Sie keine Scheuermittel oder Chemikalien Staubab...

Page 9: ...9 1 Familienhaus Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1...

Page 10: ...0 2 Familienhaus Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1...

Page 11: ...1 3 Familienhaus Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1...

Page 12: ...AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION 6 4 5 VISTUS AD 4010 Abb B DIAGRAM B ILLUSTRATION B AFBEELDING B B 7 6 3 4 5 13 12 11 14 15 INNENSTATION INDOOR STATION BO TIER INT RIEUR...

Page 13: ...SH VISTUS AD 13 Abb C DIAGRAM C ILLUSTRATION C AFBEELDING C C INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 13 13 06 1...

Page 14: ...1x Indoor station 1x Assembly materials PREPARING FOR INSTALLATION The following lines are required Single family house 3 lines from the outdoor unit to the indoor unit and 2 lines from the outdoor un...

Page 15: ...wer section from the front section press a small slotted screwdriver against the snap fastener B 15 on the bottom side 2 Use the lower section of the casing as an aid to mark the drill holes Make sure...

Page 16: ...f the PCB It is labelled with Signal GND and VCC Attach the transmitter connecting cable to the plug so that yellow is connected to Signal black to GND and red to VCC Turn the PCB over again and route...

Page 17: ...briefly in order to switch the system back to standby operation Note If a floor button is connected then an unchangeable ring tone is played when the floor button is activated This ring tone is fixed...

Page 18: ...and pockets and polystyrene parts etc could be lethal toys for children The interior unit is suitable only for dry interior rooms not bathrooms and other moist places Do not allow the devices to get m...

Page 19: ...AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION 6 4 5 VISTUS AD 4010 Abb B DIAGRAM B ILLUSTRATION B AFBEELDING B B 7 6 3 4 5 13 12 11 14 15 INNENSTATION INDOOR STATION BO TIER INT RIEUR...

Page 20: ...S AD FRAN AIS 20 Abb C DIAGRAM C ILLUSTRATION C AFBEELDING C C INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 20 13 06...

Page 21: ...ette 3 x bo tier int rieur 1 x alimentation lectrique ST 1000 1 x kit d installation Mat riel fourni avec VISTUS AD 400 1 x bo tier int rieur 1 x kit d installation PR PARATION DE L INSTALLATION Voici...

Page 22: ...visser les vis de travers Cela pourrait endommager le filetage situ au fond du bo tier MONTAGE DU BO TIER INT RIEUR Vous pouvez installer le bo tier int rieur la hauteur de votre choix afin qu il soit...

Page 23: ...ducteurs illustration A Door opener Aucune alimentation lectrique suppl mentaire n est requise pour faire fonctionner le syst me d ouverture de la porte Le syst me d ouverture de la porte est con u po...

Page 24: ...es CONFIGURATION DU BO TIER INT RIEUR Le bo tier int rieur dispose des diff rentes configurations suivantes Vous pouvez ainsi les modifier en fonction de votre environnement personnel Volume de la son...

Page 25: ...de modifications techniques et d quipement Bo tier int rieur 3 5 Alimentation 15 V CC Fonctionnement vide 0 5 W CONSIGNES L influence de forts chants statiques lectriques ou haute fr quence d charges...

Page 26: ...AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION 6 4 5 VISTUS AD 4010 Abb B DIAGRAM B ILLUSTRATION B AFBEELDING B B 7 6 3 4 5 13 12 11 14 15 INNENSTATION INDOOR STATION BO TIER INT RIEUR...

Page 27: ...ANDS VISTUS AD 27 Abb C DIAGRAM C ILLUSTRATION C AFBEELDING C C INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 27 13 06...

Page 28: ...NTAGE VAN HET BUITENSTATION De deurintercom is bedoeld voor opbouwmontage Voorbereiding Let er bij het verwijderen van de frontcover op dat de naambordjes er niet uitvallen opdat deze niet beschadigd...

Page 29: ...schroefdraad in het onderste deel van de behuizing beschadigd raken MONTAGE VAN HET BINNENSTATION De hoogte waarop de binnenstations worden gemonteerd kunt u zelf bepalen 1 De bovenste en onderste del...

Page 30: ...en 2 aderige kabel met het bui tenstation verbonden afb A Door opener Voor de bediening van de deuropener is geen extra spanningsvoorziening nodig De deuropener moet geschikt zijn voor 12 volt gelijks...

Page 31: ...ION Het binnenstation heeft de volgende mogelijkheden om het systeem aan te passen aan uw persoonlijke situatie Belvolume Het belvolume van het binnenstation wordt met een potentiometer afb C Bell Vol...

Page 32: ...ende schade of gevolgschade die direct of indirect het gevolg is van een storing van dit product in geval van een alarm NL Deze gebruiksaanwijzing is een publicatie van m e GmbH modern electronics An...

Page 33: ...family house Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1 indd...

Page 34: ...family house Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1 indd...

Page 35: ...family house Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1 indd...

Page 36: ...g mit den grundlegenden Anforderungen und den brigen einschl gigen Bestimmungen be ndet KONFORMIT TSERKL RUNG kann unter folgender Adresse gefunden werden http www m e de download ce vistus ad 4000ce...

Reviews: