background image

GB

ENGLISH  |    

VISTUS-AD

  

15

1.  Remove the two screws in order to be able to open the casing 

on the outdoor station. The casing is also fitted with notches and 
projections that connect the upper and lower parts of the casing. 
Thus a certain amount of force is necessary in order to separate the 
casing parts.

2.  Position the drilling template for the outdoor station in a level 

location at the intended assembly location (a spirit level is helpful 
for this) and attach it with sticky tape.

3.  Use the drilling template to drill the attachment holes with a 6mm 

drill and insert a dowel into each hole.

4.  Now remove the drilling template.
5.  Feed the lines through the large hole in the outdoor station and 

secure them with 4 screws.

6.  Connect the line in accordance with the wiring plan.

Adjusting the nameplate

The nameplate comprises two transparent plastic parts that are
connected with 2 or 4 small screws.

7.  Remove all screws from the nameplate and take the plate apart. 

The foil for the name can be found between the plastic parts.

8.  Write on the foil with a smudge proof felt tip pen or print a 

nameplate* using a PC and printer.

9.  Lay the complete nameplate (foil) between the two plastic parts 

and screw them back together.

* Size of the nameplate:
VISTUS AD-4010: 71 mm x 50 mm
VISTUS AD-4020: 71 mm x 25 mm
VISTUS AD-4030: 71 mm x 15mm

10. Replace the nameplate in the front cover before re-attaching 

the front cover to the outdoor station. You can attach a strip of 
sticky tape over the nameplate and the casing to ensure that the 
nameplate does not fall out during assembly.

Note

: Remove the sticky tape from the casing immediately following 

installation in order to prevent damage to the front cover!

11.  Screw the front cover on using both casing screws. Please ensure 

that the screws are not tilted as this can damage the thread in the 
lower section of the casing.

ASSEMBLY OF THE INDOOR STATION

The installation height of the Indoor stations can be selected freely 
according to your circumstances.

1.  The casing on the indoor station is kept together with notches and 

projections. To separate the lower section from the front section, 
press a small slotted screwdriver against the snap fastener (B.15) 
on the bottom side. 

2.  Use the lower section of the casing as an aid to mark the drill 

holes. Make sure that you hold the lower section in a horizontal 
position for this step.

NOTE

: The lower casing section on the indoor station can also be 

attached to a hollow wall box. The corresponding attachment holes 
are located around the line feed hole. If this does not provide 
enough hold then drill more holes and use them to also screw the 
indoor station in place.

3.  Drill the attachment holes with a 6 mm drill and insert one dowel 

in each hole.

4.  Feed the lines through the feed hole in the lower casing part 

designed for this purpose and screw this down.

5.  Attach the lines in accordance with the wiring plan and replace the 

front casing section onto the lower casing section. Make sure that 
it clicks correctly into place.

CONNECTION

An exact description of where the individual connections and terminals 
are located can be found in the figures. The recommended wiring can 
be seen in the corresponding wiring plan in the affix.

Connect the lines to the audio, +15V and GND on the outdoor station. 
These terminals are also present on the indoor stations and need to be 
connected to one another 1:1.

Note on the 2-family version

: One four-pole connection terminal 

is present in each residential unit. The connection terminals are numbe-
red. Connection terminal 1 is for the lower and connection terminal 
2 is for the upper bell button.

Note on the 3-family version

: One four-pole connection terminal 

is present in each residential unit. The connection terminals are numbe-
red. Connection terminal 1 is for the lower, connection terminal 2 is for 
the middle and connection terminal 3 is for the upper bell button.

Connecting the door opener

The door opener is connected directly to the outdoor station with two 
lines (Figure A ‚Door opener‘). No additional power supply is necessary 
in order to control the door opener. The door opener must be designed 
for 12 volt DC voltage and may not require more than 0.9A of power. 
In the event that the door opener needs to be correctly polarised then 
both connection terminals must be marked ‘lock +’ and ‘lock –‘.

VISTUS AD-400_I-Manual_210x240_Fin8-1.indd   15

13.06.13   15:30

Summary of Contents for VISTUS AD ALU-410

Page 1: ...VISTUS AD 4010 VISTUS AD 4020 VISTUS AD 4030 VISTUS AD 400 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI GEBRUIKSAANWIJZING VISTUS AD 400_I Manual_210x240_Fin8 1 indd 1 13 06 13 15 30...

Page 2: ...B AFBEELDING B A B VISTUS AD DEUTSCH DE 2 2 3 7 6 3 4 5 13 12 11 14 15 AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION 6 4 5 V...

Page 3: ...C DIAGRAM C ILLUSTRATION C AFBEELDING C C DEUTSCH VISTUS AD 3 INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 3 13 06 13...

Page 4: ...hrt werden MONTAGE DER AU ENSTATION Die T rsprechstelle ist f r eine Aufputz Montage vorgesehen Vorbereitung Achten Sie beim Abnehmen des Frontcovers darauf dass die Namens schilder nicht herausfallen...

Page 5: ...ingeltaster Anschlussklemme 3 f r den oberen Klingeltaster 1 Entfernen Sie die zwei Schrauben um das Geh use der Au ensta tion ffnen zu k nnen Das Geh use ist zus tzlich noch mit Nasen und Nuten ausge...

Page 6: ...nenstation gesteckt Abb C N here Informationen entnehmen Sie bitte der Anleitung des VTX BELL Der Stecker f r den Sender VTX Bell befindet sich auf der Vorderseite der Hauptplatine PCB Front Um den Se...

Page 7: ...rs nlichen Gegebenheiten anzupassen Klingeltonlautst rke Mit dem Potentiometer Abb C Bell Volume wird die Klingellautst rke der Innenstation eingestellt F r volle Lautst rke drehen Sie das Potentio me...

Page 8: ...nigen vom Netz trennen Stecker ziehen Die Oberfl che des Geh uses kann mit einem mit Seifenlauge angefeuchtetem weichen Tuch gereinigt werden Verwenden Sie keine Scheuermittel oder Chemikalien Staubab...

Page 9: ...9 1 Familienhaus Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1...

Page 10: ...0 2 Familienhaus Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1...

Page 11: ...1 3 Familienhaus Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1...

Page 12: ...AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION 6 4 5 VISTUS AD 4010 Abb B DIAGRAM B ILLUSTRATION B AFBEELDING B B 7 6 3 4 5 13 12 11 14 15 INNENSTATION INDOOR STATION BO TIER INT RIEUR...

Page 13: ...SH VISTUS AD 13 Abb C DIAGRAM C ILLUSTRATION C AFBEELDING C C INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 13 13 06 1...

Page 14: ...1x Indoor station 1x Assembly materials PREPARING FOR INSTALLATION The following lines are required Single family house 3 lines from the outdoor unit to the indoor unit and 2 lines from the outdoor un...

Page 15: ...wer section from the front section press a small slotted screwdriver against the snap fastener B 15 on the bottom side 2 Use the lower section of the casing as an aid to mark the drill holes Make sure...

Page 16: ...f the PCB It is labelled with Signal GND and VCC Attach the transmitter connecting cable to the plug so that yellow is connected to Signal black to GND and red to VCC Turn the PCB over again and route...

Page 17: ...briefly in order to switch the system back to standby operation Note If a floor button is connected then an unchangeable ring tone is played when the floor button is activated This ring tone is fixed...

Page 18: ...and pockets and polystyrene parts etc could be lethal toys for children The interior unit is suitable only for dry interior rooms not bathrooms and other moist places Do not allow the devices to get m...

Page 19: ...AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION 6 4 5 VISTUS AD 4010 Abb B DIAGRAM B ILLUSTRATION B AFBEELDING B B 7 6 3 4 5 13 12 11 14 15 INNENSTATION INDOOR STATION BO TIER INT RIEUR...

Page 20: ...S AD FRAN AIS 20 Abb C DIAGRAM C ILLUSTRATION C AFBEELDING C C INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 20 13 06...

Page 21: ...ette 3 x bo tier int rieur 1 x alimentation lectrique ST 1000 1 x kit d installation Mat riel fourni avec VISTUS AD 400 1 x bo tier int rieur 1 x kit d installation PR PARATION DE L INSTALLATION Voici...

Page 22: ...visser les vis de travers Cela pourrait endommager le filetage situ au fond du bo tier MONTAGE DU BO TIER INT RIEUR Vous pouvez installer le bo tier int rieur la hauteur de votre choix afin qu il soit...

Page 23: ...ducteurs illustration A Door opener Aucune alimentation lectrique suppl mentaire n est requise pour faire fonctionner le syst me d ouverture de la porte Le syst me d ouverture de la porte est con u po...

Page 24: ...es CONFIGURATION DU BO TIER INT RIEUR Le bo tier int rieur dispose des diff rentes configurations suivantes Vous pouvez ainsi les modifier en fonction de votre environnement personnel Volume de la son...

Page 25: ...de modifications techniques et d quipement Bo tier int rieur 3 5 Alimentation 15 V CC Fonctionnement vide 0 5 W CONSIGNES L influence de forts chants statiques lectriques ou haute fr quence d charges...

Page 26: ...AUSSENSTATION OUTDOOR STATION BO TIER EXT RIEUR BUITENSTATION 6 4 5 VISTUS AD 4010 Abb B DIAGRAM B ILLUSTRATION B AFBEELDING B B 7 6 3 4 5 13 12 11 14 15 INNENSTATION INDOOR STATION BO TIER INT RIEUR...

Page 27: ...ANDS VISTUS AD 27 Abb C DIAGRAM C ILLUSTRATION C AFBEELDING C C INNENSTATION INDOOR STATION BO TIER INT RIEUR BINNENSTATION Bell Volume VTX Bell 1 1 VISTUS AD 400_I Manual_210x240_Fin8 1 indd 27 13 06...

Page 28: ...NTAGE VAN HET BUITENSTATION De deurintercom is bedoeld voor opbouwmontage Voorbereiding Let er bij het verwijderen van de frontcover op dat de naambordjes er niet uitvallen opdat deze niet beschadigd...

Page 29: ...schroefdraad in het onderste deel van de behuizing beschadigd raken MONTAGE VAN HET BINNENSTATION De hoogte waarop de binnenstations worden gemonteerd kunt u zelf bepalen 1 De bovenste en onderste del...

Page 30: ...en 2 aderige kabel met het bui tenstation verbonden afb A Door opener Voor de bediening van de deuropener is geen extra spanningsvoorziening nodig De deuropener moet geschikt zijn voor 12 volt gelijks...

Page 31: ...ION Het binnenstation heeft de volgende mogelijkheden om het systeem aan te passen aan uw persoonlijke situatie Belvolume Het belvolume van het binnenstation wordt met een potentiometer afb C Bell Vol...

Page 32: ...ende schade of gevolgschade die direct of indirect het gevolg is van een storing van dit product in geval van een alarm NL Deze gebruiksaanwijzing is een publicatie van m e GmbH modern electronics An...

Page 33: ...family house Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1 indd...

Page 34: ...family house Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1 indd...

Page 35: ...family house Steckernetzteil Modell ST 1000 oder Nutschienennetzteil Modell DT 2000 Wall plug transformer model ST 1000 or din rail transformer model DT 2000 VISTUS AD 400_I Manual_210x240_Fin8 1 indd...

Page 36: ...g mit den grundlegenden Anforderungen und den brigen einschl gigen Bestimmungen be ndet KONFORMIT TSERKL RUNG kann unter folgender Adresse gefunden werden http www m e de download ce vistus ad 4000ce...

Reviews: