27-CLEANING
Technical Dept. - All rights reserved - Reproduction prohibited
CLEANING THE PIPE UNITS
For better performance of the boiler, the pipes inside the combustion chamber should be cleaned once a month.
Open the firebox door and use the brush provided to clean the 5 pipes positioned at the top inside the combustion chamber.
Brush the pipes several times so that the ash deposited inside them falls to the bottom around the brazier.
Use a vacuum cleaner to remove all fallen material.
CLEANING THE SMOKE EXTRACTOR COMPARTMENT
In the area behind ash pan “D”, there is the smoke cap “E”, which must be removed to clean the smoke extractor. Therefore:
•
loosen the screws “s”
•
remove smoke cap “E”
Now, using the nozzle of a vacuum cleaner, remove any ash and soot that may have built up in the lower exchanger indicated by the arrow.
Before putting the cap “E” back, it is recommended to change gasket “F”
Before removing ash using a vacuum cleaner, it is recommended to clean the internal walls of the stove using the supplied scraper.
CLEANING THE LOWER COM-
PARTMENT
SCRAPER