51
25-SAFETY DEVICES AND ALARMS
Technical Dept. - All rights reserved - Reproduction prohibited
ALARM ALERTS
If there is an operational anomaly, the stove enters the alarm phase displaying the problem that has taken place through a code, a brief
description of the alarm type and an acoustic warning.
The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the panel and
helpful tips to solve the problem.
MESSAGE ON DISPLAY TYPE OF PROBLEM
SOLUTION
A01
NO IGNITION
The fire does not ignite.
(without acoustic alarm)
Check the level of pellets in the hopper.
Check that the brazier is correctly positioned in its seat
and has no deposits or unburnt material.
Make sure the glow plug warms up.
Thoroughly empty and clean the brazier before
restarting.
A02
NO FLAME
The fire goes out abnormally.
(without acoustic alarm)
Check the level of pellets in the hopper.
Check that the brazier rests correctly in its seat and has
no visible deposits of unburnt pellets.
A03
SAFETY PLT (SIC1)
Pellet hopper temperature too high
The structure is too hot because the product has been
used for too long at the maximum power or there is
poor ventilation. When the stove is sufficiently cold,
clear the alarm on the stove panel or via app. Once
the alarm is cancelled, the product can be switched
on normally.
A04
FLUE GAS TEMPERA-
TURE
The temperature of the exhaust smoke has
exceeded certain preset safety limits.
The stove switches off automatically. Let the stove
cool down for a few minutes and then switch it on
again. Check the smoke expulsion and verify the type
of pellet used according to the instructions found in
Chap. 2 of this manual. If the alarm persists, contact
the service centre.
A05
OBSTRUCTION
Flue clogged - wind.
Check the smoke duct.
The smoke extractor fails to guarantee sufficient
primary air, required for correct combustion.
Draught difficulties or clogged brazier.
Check whether the brazier is clogged and clean it, if
necessary.
Check, and if necessary clean, the smoke duct and the
air inlet.
A08
SMOKE FAN
Abnormal operation of smoke fan
Check cleanliness of the smoke fan compartment
and check if dirt is blocking it. If this is not enough,
the smoke fan is faulty. Contact an authorised service
centre to have it replaced.