18
17-START&STOP
START&STOP
The START&STOP function switches off the product when it reaches the required room temperature and if the set temperature hysteresis
is also respected.
By pressing the
button the START&STOP function is started. The icon will appear for 3”, and then go back to the previous view, where
the house near the temperature turns into the
icon, as a reminder that it is activated.
When the room temperature reaches the set temperature and all the other parameters are also
respected (see the next paragraph), the equipment switches off and the display indicates the room
temperature, the current time and the STANDBY indication to indicate the standby mode, which
allows the product to turn on again as soon as the temperature drops below the set threshold or if
the intended temperature in the room increases.
The key appears steady green once the panel is activated.
Deactivate by simply pressing the button again and the house icon returns to how it was previously.
START&STOP is recommended for well-insulated rooms where even with the stove at minimum power, the temperature
will rise.
On the other hand, it is not recommended where the product is forced to switch on and off frequently (for example after
at least 1 hour of operation) because in this way, besides premature wear of the glow plug, the product never manages to
reach full efficiency and temperature, thereby causing greater accumulation of ash or even condensation.