53
25-SAFETY DEVICES AND ALARMS
Technical Dept. - All rights reserved - Reproduction prohibited
MESSAGE ON DISPLAY TYPE OF PROBLEM
SOLUTION
A20
AUX PROBE
Auxiliary probe failure
Possible component fault.
Check that the probe inserted in the system respects
the characteristics specified in the instructions (see
external probe).
Contact an authorised service centre to have the
component checked and, if needed, replace the
component.
A21
P R E S S U R E
SWITCHES (SIC3)
Open stove door
Close the door
Open fuel loading hatch
Close the hatch.
Lower the fuel level in the hopper.
Air pressure switch
Draught difficulties or clogged brazier. Check whether
the brazier is clogged by deposits and clean it, if
necessary.
Check and if necessary clean the smoke duct and air
inlet.
A22
Room probe failure
Possible fault in the safety component. Contact an
authorised service centre to have the component
checked and, if needed, replace the component.
A23
Brazier not closed
Possible obstruction in the brazier. Clean.
If the problem persists, contact a service centre..
A24
Pump blocked
Possible component fault.
Contact an authorised service centre to have the
component checked and, if needed, replace the
component.
Summary of Contents for SUITE-CLUB Hydromatic 24 ACS M2
Page 67: ......