background image

11

Outlines and Dimensions

15

15

WATER SUPPLY

CONNECTION Rc 3/4

WATER RETURN

CONNECTION Rc 3/4

CONDENSATE

DRAIN R 3/4

6-R5*16

MOUNTING HOLES

FILTER

TERMINAL BOX

FAN MOTOR

FAN

38

187

190

D

E

F

G

H

I

20

262

131

K

J

25

24

A(A1)

B

46

C

a

MODEL

A

A1

B

C

D

E

F

G

H

I

J

K

Fan No.

Filters

Size

Qty

200D

714

814

484

448

487

547

534

150

251

105.5

143

218

1

502x244x25

1

300D

934

1034

704

668

707

767

534

150

251

105.5

143

218

2

722x244x25

1

400D

1014

1114

784

748

787

847

534

150

251

105.5

143

218

2

802x244x25

2

500D

1114

1214

884

848

887

947

534

150

251

94

143

218

2

902x244x25

2

600D

1214

1314

984

948

987

1047

534

150

251

94

143

218

2

1002x244x25

3

800D

1464

1564

1234

1198

1237

1297

534

150

251

94

143

218

3

1252x244x25

3

900D

1564

1664

1334

1298

1337

1397

534

150

251

94

143

218

3

1352x244x25

3

1000D

1664

1764

1434

1398

1437

1497

534

150

251

94

143

218

4

1452x244x25

3

1200D

1464

1564

1234

1198

1237

1297

599

200

295

94

193.8

262

3

1252x288x25

3

1400D

1664

1764

1434

1398

1437

1497

599

200

295

94

193.8

262

3

1452x288x25

3

Notes:

1.  All dimensions are in mm;

2.  All standard units are with back air plenum and bottom removal filters;

3.  A1 is the dimension for 100mm extended drain pan units;

4.  Left hand coil connection shown;

5.  Wiring connection side is the same as coil and drain connections. 

Summary of Contents for MCW1000D

Page 1: ...ING CONCEALED Chilled Water Fan Coil Unit Models MCW200D MCW800D MCW300D MCW900D MCW400D MCW1000D MCW500D MCW1200D MCW600D MCW1400D Technical Manual Engineered for flexibility and performance TM MCWD...

Page 2: ...in illustrations cover the general appearance of McQuay International products at the time of publication We reserve the right to change design and construction specifications at any time without noti...

Page 3: ...ler L Extended Drain Pan Controller M Extended Drain Pan 2 Way Valve Controller N Extended Drain Pan 3 Way Valve Controller O Standard Drain Pan 2 Way Valve Controller P Standard Drain Pan 3 Way Valve...

Page 4: ...customer requirements the new FCUs adopt the most reasonable and optimization water circuit design and utilize the national level thermal test room to guarantee both the perfect performance and a low...

Page 5: ...75 75 75 75 75 75 in wg 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 RATED POWER INPUT W 74 98 107 123 167 268 275 304 501 555 SOUND PRESSURE LEVEL DB A 42 9 43 1 45 9 46 2 47 9 50 0 48 8 49 1 53 3 53 0 C...

Page 6: ...n TESTING PRESSURE Pressure test 3 3MPa for 1 minute Leakage test 1 6MPa for 5 minutes TUBE MATERIAL COPPER DIAMETER mm 9 52 in 3 8 THICKNESS mm 0 3 in 0 012 FIN MATERIAL ALUMINIUM THICKNESS mm 0 11 i...

Page 7: ...20 46 9 21 30 40 41 41 38 32 24 46 6 MEDIUM 21 31 40 42 41 38 28 19 46 5 21 31 40 41 40 38 31 23 46 2 LOW 18 29 38 40 39 35 25 16 44 4 20 30 38 40 38 36 28 19 44 6 600D HIGH 22 31 41 42 43 40 30 20 4...

Page 8: ...5 14 5 3 4 2 4 0 344 15 8 MCW500D 75 24 0 17 9 5 5 14 5 3 8 2 7 0 389 7 2 MCW600D 75 24 0 17 9 5 5 14 5 5 0 3 7 0 482 11 4 MCW800D 75 24 0 17 9 5 5 14 5 6 2 4 6 0 618 10 0 MCW900D 75 24 0 17 9 5 5 14...

Page 9: ...783 1651 1536 1420 1408 1347 1241 1120 L 1496 1413 1365 1281 1233 1143 1096 1088 1002 892 900D H 2197 2113 2027 1920 1795 1683 1622 1560 1455 1325 M 2078 1994 1902 1814 1685 1586 1538 1477 1370 1247 L...

Page 10: ...ING LIMITS Maximum water side pressure 16 bar Minimum entering water temperature 3 C Maximum entering water temperature 95 C Minimum air inlet temperature 5 C Maximum air inlet temperature 43 C Power...

Page 11: ...30 40 50 60 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Water Flow m 3 h Water Pressure Drop kPa 400D 300D 200D 600D 500D 900D 800D 1400D 1200D 1000D Note The press...

Page 12: ...51 94 143 218 2 902x244x25 2 600D 1214 1314 984 948 987 1047 534 150 251 94 143 218 2 1002x244x25 3 800D 1464 1564 1234 1198 1237 1297 534 150 251 94 143 218 3 1252x244x25 3 900D 1564 1664 1334 1298 1...

Page 13: ...series H M L are connected to SHF HF MF respectively MODEL MCW 200 1400 POWER SOURCE ORANGE DRAWING NO M08024067082 N L MF LF SHF HF L M BROWN H YELLOW FAN BLACK FAN SPEED SWITCH NOTE MOTOR 1 BLACK F...

Page 14: ...to the carrier with a formal claim LOCATION Before installation please check the following 1 There must be enough space for unit installation and maintenance Please refer to the unit s drawings and di...

Page 15: ...IPE CONNECTION 1 Using suitable fittings as water pipe connections Refer to the specification 2 The water inlet is on the bottom while outlet on top 3 The connection must be concealed with rubberized...

Page 16: ...15 Exploded view Part List 8 FAN 6 FILTER 7 MOTOR 2 FANDECK 4 PLENUM 1 TOP PLATE 3 DRAIN GUIDE PLATE 5 COIL 9 DRAIN PAN 10 HEDER OUTLET 11 HEADER NLET...

Page 17: ...4061142 M02124061198 M02124061198 MODEL 800D 900D 1000D 1200D 1400D 1 TOP PLATE PART NO M01014060796 M01014060797 M01014060798 M01014060796 M01014060798 2 FAN DECK PART NO M01014060806 M01014060807 M0...

Page 18: ...amless copper tubes slit type aluminum blue fins bonded to the tubes by mechanical expansion Each coil has a manual air vent and two Rc3 4 water pipe connections with a working pressure of 1 6MPa 3 Fa...

Page 19: ...ect at the time of going to press we are constantly striving for improvement and therefore reserve the right to alter model specifications and equipment without notice Details of specifications and eq...