The most common causes of air conditioner failure to “start” are :
a) Voltage not / 10% of rated voltage.
b) Power supply interrupted.
c) Control settings improper
d) Air Conditioner is disconnected from main power source.
e) Fuse blown or circuit breaker off.
II) Diagnosis Of Refrigerant Circuit /Application
There might be some cases where the unit starts running but does not perform satisfactory, i.e. insufficient
cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge
air as well as running current.
Insufficient Cooling
Unit Starts
Excessive heat
source e.g. electric
kettle
High cooling load
Refrigerant circuit
Leakage
Restriction e.g. at
strainer, capillary,
filter dryer, etc.
Compressor
Less or no compression
(Low running current)
Room overcrowded
with people
Windows / doors
wide open
Check air circulation
Indoor/Outdoor coil dirty
(clogged)
Air filters dirty
Fan Malfunction
Obstruction at air inlet/outlet
of indoor/outdoor unit
Satisfactory operation with temperature difference of
air intake & discharge of indoor unit 10°C - 15°C
Insufficient Heating
Unit Starts
High heating load
Refrigerant circuit
Leakage
Restriction e.g. at
strainer, capillary,
filter dryer, etc.
Compressor
Less or no compression
(Low running current)
Windows / doors
wide open
Check air circulation
Indoor/Outdoor coil dirty (clogged)
Air filters dirty
Fan Malfunction
Obstruction at air inlet/outlet
of indoor/outdoor unit
Satisfactory operation with temperature difference of
air intake & discharge of indoor unit 16°C - 25°C
Summary of Contents for M5WM 007G
Page 42: ...Cooling Only Models Model MLC M5LC 020C M4LC 020B Model MLC M5LC 025C M4LC 025B 40...
Page 43: ...Heatpump Models Model MLC M5LC 007CR Model M4LC 007BR 010BR MLC M5LC 010CR 41...
Page 44: ...Model M4LC 015BR Model MLC M5LC 015CR 42...
Page 45: ...Heatpump Models Model MLC M5LC 020CR M4LC 020BR Model MLC M5LC 025CR M4LC 025BR 43...
Page 53: ...Cooling Only Models Outdoor Unit Model MLC 015C 51 Indoor Unit Model MWM 015G With Ionizer...
Page 56: ...Cooling Only Models Outdoor Unit Model MLC 015C 54 Indoor Unit Model MWM 015G With NTP...
Page 62: ...60 Cooling Only Models Outdoor Unit Oxygen Unit Model MLC 010C M5LC 010C 015C...
Page 64: ...62 Heatpump Models Outdoor Unit Model MLC 015CR Indoor Unit Model MWM 015GR With Ionizer...
Page 67: ...65 Heatpump Models Outdoor Unit Model MLC 015CR Indoor Unit Model MWM 015GR With NTP...
Page 79: ...77 Installation Diagram Installation...
Page 100: ...98 Model M5WM MWM 020G 020GR 025G 025GR...
Page 118: ...2005 McQuay International 1 800 432 1342 www mcquay com...