Extreme Series 10.1" Monitor/DVR System
© 2022 McNeilus Truck and Manufacturing, Inc.
10
Installation
Power Accessory Harness
1
2
3
4
5
6
7
8
9
10
11
12
13
Front view
800±20
2000±50
OD 6.5
K279
13P female plug
Half peeled 10mm
Brown
White
Black
Gray
Purple
Green
Blue
Yellow
Label: CAM1
Label: CAM2
Label: GND
Label: CAM3
Label: CAM4
Label: CAM5
Label: CAM6
Label: BATT+
Red
Label: ACC
Wire
Function
Note
RED
ACC POWER
Connect to Ignition Power Source
BLACK
GROUND
Connect directly to the battery ground or to a good chassis
ground
YELLOW
BATTERY
Connect to the battery or a constant power source to ensure
your monitor settings do not reset if the monitor is turned off for
an extended period of time, and/or will allow the DVR system
to operate when LCD screen if off.
NOTE:
The following wires only need to be used if you desire the camera to display when the vehicle is in a
specific operation (e.g., Reverse).
BROWN
REVERSE / BACK UP
(CAMERA 1)
If you want this camera to be activated and displayed when the
truck is in Reverse, connect the BROWN wire to a Reverse/
Back Up signal
WHITE
LEFT TURN
(CAMERA 2)
If you want this camera to be activated and displayed when the
Left Direction Turn Signal is activated, connect the White wire
to the directional signal Left.
GRAY
RIGHT TURN
(CAMERA 3)
If you want this camera to be activated and displayed when the
Right Direction Turn Signal is activated, connect the Gray wire
to the directional signal Right.
PURPLE
FRONT / HOPPER
(CAMERA 4)
If you want this camera to be activated and displayed when the
truck is in Drive, connect the Purple wire to a Power signal.
GREEN
PARK
(CAMERA 5)
If you want this camera to be activated and displayed when the
truck is in Park, connect the Green wire to a Park signal.
BLUE
MISC
(CAMERA 6)
If you want this camera to be activated and displayed, connect
the Blue wire to a power signal.
NOTE:
When a trigger wire is activated, that camera takes precedence over all other recording options for the
period of time that the trigger wire is activated.
NOTE:
Using a directional turn signal to activate a camera will require the use of the 2-second off delay
programmable in Settings.
NOTE:
The yellow wire must be connected to the battery or a constant power source to ensure your monitor
settings are retained and also to allow certain recording options to function when the LCD screen is turned off
(see Ignition Off Setup).