Fusing the Pipe (Positive Vertical Fusion Pressure)
NOTICE:
Failure to follow pipe manufacturer's fusion procedures
may result in a questionable joint.
After following the pipe manufacturer's suggested heating
procedure:
A
) Shift the carriage directional control to neutral position.
B
) Shift the pressure selector to the facing position.
C
) Open the carriage just enough to remove the heater.
Quickly remove the heater. Inspect pipe ends for appropriate
melt.
Acrobat 250 and 315: Quickly remove the heater by grabbing
the heater latch and pulling it into the handle of the heater to
release from the guide rod. Inspect pipe ends for appropriate melt.
D
) Shift the pressure selector control to fusing pressure.
E
) Quickly close the carriage, bringing the pipe ends together under the
vertical fusion pressure.
Allow joint to cool under pressure according to pipe manufacturer’s
or appropriate joining standard's recommendations.
TX04835-12-21-17
CD013
82
-10
-5-15
CD014
38-11-18-15
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
Special Operations - Vertical Fusion (Movable Pipe Above)
5 - 9
C
A
B
D
E
FUSES
MOTOR
POWER
SUPPLY
CD018
92
-12
-0
7-16
A C
B
E
D
Acrobat HPU
DynaMc EP HPU
Summary of Contents for A714201
Page 78: ......