Inserting Heater
The heater is not explosion proof. Operation
of heater in an explosive atmosphere without
necessary safety precautions will result in serious
injury or death. Refer to Special Operation
- Fusion in Explosive Atmosphere for safety
precautions.
Use a clean dry lint free non-synthetic cloth to clean the butt fusion
heater adapter surfaces.
Place the heater between the two pipe ends.
Acrobat 250 and 315
Ensure the heater latch locks onto the carriage guide rod.
TX04826-12-21-17
Special Operations - Vertical Fusion (Movable Pipe Below)
4 - 7
CD013
84
-10
-5-15
¡PELIGRO!
Check Heater Temperature
NOTICE:
Incorrect heating temperature can result in
questionable fusion joints. Check heater plates periodically
with a pyrometer and make necessary adjustments.
Refer to the "Maintenance" section of this manual for instructions
how to adjust heater temperature.
Check heater surface temperature with a pyrometer.
Refer to the pipe manufacturer's recommendations or appropriate
joining standard for proper heater temperature.
IMPORTANT:
The dial thermometer on the heater indicates internal
temperature which varies from the actual surface temperature.
The dial thermometer can be used as reference once the surface
temperature has been verified and is never a substitute for actual
surface temperature.
TX04011-4-12-10
WR000
77
-4
-16
-9
3
PH00
42
0-11-1-9
4
Summary of Contents for A714201