ELECTRICAL CABLE CONNECTIONS
Copyright © 2018 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer.
Any published technical data and instructions are subject to change without notice. Contact your McCrometer representative
for current technical data and instructions.
www.mccrometer.com
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
Lit. # 30122-46 Rev. 1.2 / 5-31-18
17
Figure 16. Converter Grounding With Cable Lug For FPI Mag
395L and Ultra Mag Body Style 1
Figure 15. Converter Grounding With Cable Lug For FPI
Mag 395L and Ultra Mag Body Style 2
5.6
Converter Grounding
5.6.1 Converter Grounding For FPI Mag 395L and Ultra Mag Body Style 2
Cable B
Enclosure
Ground Lug
Black Ground
Wire With Loop
From Cable B
With Lead To
Terminal #3
Cable B
Enclosure
Ground Lug
Black Ground
Wire With Loop
From Cable B
On converters attached to the
395L and Ultra Mag body style 2
flow meters, the sensor cable has
a ground wire fitted with a loop.
Attach the wire with the loop to the
enclosure's ground terminal lug as
shown in Figure 15.
5.6.2 Converter Grounding For Ultra Mag Body Style 1
On converters attached to the Ultra
Mag body style 1 flow meters, the
sensor cable has a ground wire fitted
with a loop and a terminal extension.
Attach the wire to the enclosure's
ground terminal lug as shown in
Figure 16 via the wire end loop,
then connect the wire extension to
Terminal #3.