3.2.2 RPM sensor installation examples
The inductive turbine RPM sensor (and distributor RPM sensor, if present) (see
chapter “General description” on page 7) must be placed opposite a metal reference
having a diameter at least as large as the respective sensor (12 mm) and protruding
from any other metal body by at least 7 mm. The gap between the sensor and its
respective metal reference should be 2 to 3 mm.
The figures below show two different installation examples.
Figure 5.
Ø
18 Inductive sensor installed on PTO.
Figure 6. Ø12 Inductive sensor installed on gearbox.
!
Warning
We recommend protecting the sensor cable with a rubber sheath.
Bolt
Bushing
RPM sensor
RPM sensor
Bushing
Bolt
2-3 mm
PTO connection
2mm
1.2mm
Ex. : Gearbox