Installation and use
11
SEEDER MAT MCK 2500 SX
Plug the connector of the inductive (or magnetic) distributor RPM sensor into the
“Fan”
connector
(D)
on the seed drill.
Plug the connector of the capacitive seed level sensor (code 1403) into the
“Level”
connector
(E)
on the seed drill. Note: If you do not plan to use the seed
level alarm function BUT you still want to use the other warning functions, the
connector
(E)
on the wiring harness must be fitted with a jumper, available on
request (code 00SEN-JUMPER3VF-0001).
Connect the
“Left Motor” (F)
and
“Right Motor” (G)
cables to the shut-off
devices on the seed drill. Different kinds of wiring harnesses are available
depending on the type of shut-off devices installed. The table below shows the
harnesses corresponding to different shut-off devices. If you are using the
specific
MC Elettronica
shut-off valves, you only need to plug the connectors on
the valves into the connectors on the harness. If you are using another kind of
motorized shut-off valves, connect cables
(F)
and
(G)
directly to the wires on the
valves, which should be provided with a suitable connector. If you are using
solenoid valves, cables
(F)
and
(G)
will be fitted with DIN connectors, so you can
simply plug the connectors directly into the solenoid valves.
Wiring harness code
Connectors on
cables (F) and
(G)
Corresponding shut-off
device
10CAB-MCK2500-
0001
4 x
2-way AMP S.Seal
Standard MC Elettronica devices
Wiring scheme (MOTORS):
Shut-off row Sowing row
M
+
-