Copyright 2016 MBW Technologies, LLC All Rights Reserved 

Digital Input Setup 

 
The DI1 and DI2 Setup 
Menus are used to program 
the operation of the two 
discrete inputs.  
 
 
 
 
 

Digital Input Functionality 

The digital input functionality must be configured 
and a wide range of selections are made available 
to the user providing the   flexibility to match their 
specific application. These inputs should be 
configured before activating the system. First the 
functionality of the digital input must be configured.  
The choices are; “Off”, “Start”, “Stop”, “Start/Stop”, 
“Speed 1”, “Speed 2”, “Speed 3” and “Start Inhibit” 
(Start Inhibit) as defined in Table 3. 
 
Use the “

” or “

” keys to highlight the desired function. Press and hold 

MODE

 key to save changes. 

Table 3. Digital Input Functionality 

OFF – Disables the discrete input 

Start – When configured to Start, DI1 or DI2 will be used to Start the engine. 

Stop - When configured to Stop, DI1 or DI2 will be used to Stop the engine. 
 

Note: For safe operation in A/S mode be sure to set one DI to a setting of 

“Start/Stop” or “Stop”.

 

Start/Stop - When configured to Start/Stop, DI1 or DI2 will be used to Start the 
engine when the active state occurs and then Stop the engine when active state 
goes inactive.  

Speed 1 - When configured to Speed 1, DI1 or DI2 will ramp the engine to the 
Speed 1 setting. 

Speed 2 - When configured to Speed 2, DI1 or DI2 will ramp the engine to the 
Speed 2 setting. 

Speed 3 - When configured to Speed 3, DI1 or DI2 will ramp the engine to the 
Speed 3 setting. 

Start Inh - When configured to Start Inh (i.e., Start Inhibit), the engine will not start. 

M300DP L Series Expansion I/O Module – Installation / User Manual 

 

Copyright 2016 MBW Technologies, LLC All Rights Reserved

                                

 23

 

Technical Specifications 

Parameter 

Specification 

Operating Voltage 

9 to 32 VDC 

Communication 

J1939 CAN 2.0B 

Operating Temperature 

-30C to +70C (-22F to 158F) 

Storage Temperature 

-40C to +80C (-40F to 176F) 

Reverse Polarity Protection 

Yes 

Salt Spray 

IEC60068-2-52: 1996

0.18 Dia or # 

8 screw 
No Tests Performed

 

EMC 

IEC61000 and EN55022 
No Tests Performed 

Degree of Protection 

IP67

 

Dimensions  

102.294mm x 53.39mm x 27.3mm 
(4.053” x 2.102” x 1.075”)

 

System Protection 

Provided externally

 

 

System Components  

Part Number  Description 

M300DP Expansion I/O Module 

/AS Add M300DP to any M150B or M150L Series product 

MN10036 Manual – User M154L Yanmar T4F 
MN10047 Manual – M300DP Expansion I/O Control for B Series Panels 
MN10058 Manual – M300DP Expansion I/O Control for L Series Panels 
MN10060 Data Sheet – M300DP Expansion I/O for L Series Panels 

 

 

 

Summary of Contents for M300DP

Page 1: ...016 MBW Technologies LLC All Rights Reserved P N MN10058 00 AIt Email sales mbwtech com Phone 267 932 8573 x340 www mbwtech com MBW Technologies LLC Installation User Manual M300DP Expansion I O Modul...

Page 2: ...RRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Statements made...

Page 3: ...Expansion I O Module Installation User Manual Copyright 2016 MBW Technologies LLC All Rights Reserved 3 Table of Contents Quick Start Guide 5 Powering the System 6 Changing Data Displays 6 MP300DP Sys...

Page 4: ...puts White Black White Black Common Common connects to Throttle Switch Black Mechanical Mounting The Auto Start module has two mounting holes 0 18 Diameter or 8 screws The mechanical dimensions are sh...

Page 5: ...cations are shown in Table 4 The installer is responsible for making the connection from each pigtail to the device s Oil Pressure Sender Fuel Sender Float Switch etc Figure 3 Engine Connector Pigtail...

Page 6: ...ed for the Auto Start module 1 Remove the wedgelock and the Yellow wire from the P3 connector and insert the Yellow wire from the Auto Start module into the vacated pin location Pin 3 2 Remove the Gre...

Page 7: ...tallation User Manual Copyright 2016 MBW Technologies LLC All Rights Reserved 7 MP300DP System Operation Menu Navigation The Mode Button is multi functional and is used as an escape and enter key When...

Page 8: ...ies Expansion I O Module Installation User Manual Copyright 2016 MBW Technologies LLC All Rights Reserved 29 Appendix B Field Installation Making the Connections The Expansion I O Module shown in Figu...

Page 9: ...discrete input wires are inserted into the correct pin locations of the Engine Connector The data for the senders on to an analog input does not show up as an Engine parameter Make sure the analog in...

Page 10: ...I1 regardless of whether it has been configured to Speed 1 or Speed 2 The throttle switch has priority over both DI1 and DI2 Table 1 DI1 and DI2 Setup Stop When configured to Stop DI1 or DI2 will stop...

Page 11: ...red active state Press and hold MODE key to save selection On Delay s The On Delay parameter controls how long 0 to 60 0 seconds the active state is present before action is taken Use the or keys to a...

Page 12: ...rs Use the or keys to highlight the desired sender type Press and hold MODE key to save changes Start Retries The number of engine start cycles to be executed after the initial AutoStart A S sequence...

Page 13: ...ncrements of 50 RPMs Speed 1 2 and 3 are bounded by the Engine MIN MAX RPM range in the Engine menu Note range of rpm settings may vary based on engine model Use the or keys to set the RPM for Speed 1...

Page 14: ...the active state occurs and then Stop the engine when active state goes inactive Speed 1 When configured to Speed 1 DI1 or DI2 will ramp the engine to the Speed 1 setting Speed 2 When configured to S...

Page 15: ...lly Closed N C contact The active state for a N O switch should be set to Closed closure to ground and the active state of a N C switch should be set to Open input is open On Off Delay s The On Off De...

Page 16: ...nstallation section of this manual for more information Selecting A S enables the AutoStart Mode Note A S is not activated until key switch is in Auto Position M300DP L Series Expansion I O Module Ins...

Page 17: ...icate an impending engine start sequence by generating a countdown sequence to engine start If the system has been wired for an alarm an audible alarm will be heard during this time See the Installati...

Page 18: ...system Recommended order 1 Verify the battery battery switch connections to engine per the engine installation diagram Refer to engine manufacturer installation manual Verify engine is bonded to batte...

Reviews: