Default Settings 

Upon receiving the Auto Start module, the unit will be set to the following 
values. Setting the module back to defaults is made by using the 
RESTORE DEFAULTS which is under the ENGINE SETTINGS menu 
level. 
 

Parameter 

Default Value 

Display Settings 

 

M300 Mode 

OFF 

Speed 1 

Engine Min RPM 

Speed 2 

1500 RPM 

Speed 3 

Engine Max RPM 

Throttle Profile 

 

Speed1 (s) 

Speed1 Ramp (s) 

Speed2 (s) 

Speed2 Ramp (s) 

Speed3 (s) 

Stop (s) 

DI1 Setup 

OFF 

DI2 Setup 

OFF 

AI1 OFF 
AI2 OFF 
A/S Delay (s) 

10 

Start Retries 

 

 

 

M300DP L Series Expansion I/O Module – Installation / User Manual 

 

Copyright 2016 MBW Technologies, LLC All Rights Reserved

                                

 13

 

Speed Settings 

The A/S Mode supports three different engine speed settings.  These 
settings can be used in the throttle profile and in the remote speed 
assignments. The speed values (RPM) may be programmed from 600 to 
3150 in increments of 50 RPMs.   Speed 1, 2, and 3 are bounded by the 
Engine MIN/MAX RPM range in the Engine menu. 

(Note: range of rpm settings may vary based on engine model.) 

 
 
 
 
 
 
 
Use the “

” or “

” keys to set the RPM for Speed 1, 2, and 3. Press and 

hold 

MODE

 key to save each selection. 

Throttle Profile 

When the AutoStart input is activated, a Throttle Profile is used to control 
the engine speed over a series of steps. The profile has 5 settings which 
are described in Table 2 below.  Use the “

” or “

” keys to set the 

desired time for each stage of the Throttle Profile. Press and hold 

MODE

 

key to save each selection. 
 
 
 
 
 
 

 

Note: If a Throttle Profile Segment time is set to zero, that segment of the 
profile will be skipped. 

 

Table 2 - Throttle Profile Setup 

Speed1 (s) – This parameter determines how many seconds the engine 
will run at Speed1. 

Ramp->Speed2 (s) – This parameter determines the ramp time from 
engine Speed 1 to Speed 2 in seconds. 

Speed2 (s) – This parameter determines how many seconds the engine 
will run at Speed2. 

Ramp->Speed3 (s) – This parameter determines the ramp time from 
engine Speed 2 to Speed 3 in seconds. 

Ramp->Min (s) – This parameter determines ramp time from current 
speed to the Min RPM value in Engine menu. 

Summary of Contents for M300DP

Page 1: ...016 MBW Technologies LLC All Rights Reserved P N MN10058 00 AIt Email sales mbwtech com Phone 267 932 8573 x340 www mbwtech com MBW Technologies LLC Installation User Manual M300DP Expansion I O Modul...

Page 2: ...RRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Statements made...

Page 3: ...Expansion I O Module Installation User Manual Copyright 2016 MBW Technologies LLC All Rights Reserved 3 Table of Contents Quick Start Guide 5 Powering the System 6 Changing Data Displays 6 MP300DP Sys...

Page 4: ...puts White Black White Black Common Common connects to Throttle Switch Black Mechanical Mounting The Auto Start module has two mounting holes 0 18 Diameter or 8 screws The mechanical dimensions are sh...

Page 5: ...cations are shown in Table 4 The installer is responsible for making the connection from each pigtail to the device s Oil Pressure Sender Fuel Sender Float Switch etc Figure 3 Engine Connector Pigtail...

Page 6: ...ed for the Auto Start module 1 Remove the wedgelock and the Yellow wire from the P3 connector and insert the Yellow wire from the Auto Start module into the vacated pin location Pin 3 2 Remove the Gre...

Page 7: ...tallation User Manual Copyright 2016 MBW Technologies LLC All Rights Reserved 7 MP300DP System Operation Menu Navigation The Mode Button is multi functional and is used as an escape and enter key When...

Page 8: ...ies Expansion I O Module Installation User Manual Copyright 2016 MBW Technologies LLC All Rights Reserved 29 Appendix B Field Installation Making the Connections The Expansion I O Module shown in Figu...

Page 9: ...discrete input wires are inserted into the correct pin locations of the Engine Connector The data for the senders on to an analog input does not show up as an Engine parameter Make sure the analog in...

Page 10: ...I1 regardless of whether it has been configured to Speed 1 or Speed 2 The throttle switch has priority over both DI1 and DI2 Table 1 DI1 and DI2 Setup Stop When configured to Stop DI1 or DI2 will stop...

Page 11: ...red active state Press and hold MODE key to save selection On Delay s The On Delay parameter controls how long 0 to 60 0 seconds the active state is present before action is taken Use the or keys to a...

Page 12: ...rs Use the or keys to highlight the desired sender type Press and hold MODE key to save changes Start Retries The number of engine start cycles to be executed after the initial AutoStart A S sequence...

Page 13: ...ncrements of 50 RPMs Speed 1 2 and 3 are bounded by the Engine MIN MAX RPM range in the Engine menu Note range of rpm settings may vary based on engine model Use the or keys to set the RPM for Speed 1...

Page 14: ...the active state occurs and then Stop the engine when active state goes inactive Speed 1 When configured to Speed 1 DI1 or DI2 will ramp the engine to the Speed 1 setting Speed 2 When configured to S...

Page 15: ...lly Closed N C contact The active state for a N O switch should be set to Closed closure to ground and the active state of a N C switch should be set to Open input is open On Off Delay s The On Off De...

Page 16: ...nstallation section of this manual for more information Selecting A S enables the AutoStart Mode Note A S is not activated until key switch is in Auto Position M300DP L Series Expansion I O Module Ins...

Page 17: ...icate an impending engine start sequence by generating a countdown sequence to engine start If the system has been wired for an alarm an audible alarm will be heard during this time See the Installati...

Page 18: ...system Recommended order 1 Verify the battery battery switch connections to engine per the engine installation diagram Refer to engine manufacturer installation manual Verify engine is bonded to batte...