INSTRUCTIONS FOR INSTALLATION AND USE
Connection to Internal Chimney
Image 7 shows the correct way to connect the stove to
the internal chimney. 80 mm diameter flue ducts are
used for connection within a room. The ducts do not
have to be insulated, but it is important to provide
adequate sealing at the duct connections.
A condensation system is also mandatory to avoid
problems in operation. The top of the chimney must be
fitted with a cap for rain and wind protection, and if the
chimney is exposed to outside conditions, it must be
insulated.
Image 7