SAFETY
FRONT VIEW
13
14
15
16
17
BACK VIEW
18
18
19 20
21
13. EVAP Testing Indicator
Indicates EVAP / Low Pressure testing selected
14. System Pressure
System compound pressure gauge EVAP
15. Flow Meter
Measures flow rate into system under test
16. EVAP / Low Pressure Vapor Output Hose
Delivers low pressure vapor into system under test
17. EVAP/Low Pressure Flow Control Valve
(Variable)
Releases vapor / pressure into the system.
Close flow control valve to lock out system for
pressure decay testing
*NOTE
: During EVAP testing, the output pressure
is fixed and cannot be adjusted. Adjustable
regulator is only used during high pressure testing.
REAR / BACK VIEW
18. Fluid Fill Ports (2x)
Remove fluid fill plug to fill machine with OE
approved vapor producing agent
19. International AC Power Inlet (100-240V)
AC power cable inlet
20. Fuse Holder
10A 250V Fuse plus one spare fuse
21. Compressed Air Inlet
Replace coupler fitting if necessary. Male 1/4 in.
NPT fitting
EVAP/LOW PRESSURE
*