6-5
Input voltage
200V
220V
Power cable
38 mm
2
(0.6 in
2
)
Power source
connection cables
(Ambient
temperature: 30°C
(86°F) or lower)
Grounding cable
22 mm
2
(0.3 in
2
)
6-2-3
Air Source Requirements
Pressure
5.0 - 9.0 kgf/cm
2
(71.2 - 128.1 PSI)
Minimum discharge Standard
140 L/min (4.942 ft
3
/min)
With air blast option 722 L/min (25.487 ft
3
/min)
Dew point
−
17°C (30.6°F) or lower (at atmospheric pressure)
Note:
If the air has a high moisture content or if hot air is used, air actuators and equipment
could be damaged. In such cases, use an air dryer or similar equipment.
6-2-4
Items to Be Confirmed when Carrying the Machine
1.
Machine dimensions
In order to carry this standard machine into your plant, the entrance of your plant must be bigger
than the dimensions indicated below:
Unit: mm (in.)
Dimensions
Status
Application
Type B
Normal dimensions
(Z-axis lowest position)
Overall width
:2996 (117.95 in)
Overall height
:2553.5 (100.53
in)
Crosswise
:2855 (112.40 in)
Dimensions when the machine is
carried in/out by truck
Dimensions after the followings are
dismounted:
・
Operation panel handle
・
Rear
cover
Overall width
:2939 (115.71 in)
Overall height
:2553.5 (100.53
in)
Crosswise
:2834.6 (111.60
in)
Return to Library
Summary of Contents for VTC-160A
Page 2: ...Notes Return to Library...
Page 20: ...Notes Return to Library...
Page 54: ...4 20 MEMO Return to Library...
Page 61: ...5 7 5 4 3 Hydraulic Circuit Diagram Return to Library...
Page 74: ...5 20 MEMO Return to Library...
Page 82: ...6 8 Machine body Fig 6 1 Lifting the Machine Return to Library...
Page 96: ...7 4 MEMO Return to Library...