4-2
4-2 Table of Inspection and Maintenance Items
Symbol “
○
” indicates the inspection interval.
Approximate Operating Hours
Inspection/Maintenance Intervals
Items
Daily
Weekly
60 H
Monthly
250 H
Every 6
months
1500 H
Every year
3000 H
Every 2
years
6000 H
Refer to
Inside the Machine
1. Removing
accumulated
chips
(including chips within the magazine)
○
4-3-1
2. Cleaning the window in the
operator’s door
○
4-3-1
Outside the Machine
1. Disposing of chips accumulated in
the chip bucket
○
4-3-2
2. Cleaning the plate filters in the
coolant tank
○
4-3-2
3. Cleaning the filer of the spindle
cooling unit
○
4-4-1
Checking Oil Levels
1. Checking the hydraulic oil level
○
4-3-3
2. Checking the spindle cooling fluid
level
○
4-3-3
3. Checking the centralized lubricating
oil level
○
4-3-3
4. Checking the coolant level
○
4-3-3
Checking Pressures (Hydraulic and Air)
1. Checking the hydraulic unit oil
pressure
○
4-3-4
2. Checking the air pressure
○
4-3-4
Changing or Replenishing Oils
1. Replenishing coolant (As needed)
○
4-3-5
2. Replenishing
the
centralized
lubricating oil level
○
4-5-1
3. Changing hydraulic oil and cleaning
the filters
○
4-6-1
4. Changing hydraulic oil of ATC unit
○
4-6-1
5. Changing spindle cooling fluid and
cleaning the filters
○
4-7-1
Return to Library
Summary of Contents for VTC-160A
Page 2: ...Notes Return to Library...
Page 20: ...Notes Return to Library...
Page 54: ...4 20 MEMO Return to Library...
Page 61: ...5 7 5 4 3 Hydraulic Circuit Diagram Return to Library...
Page 74: ...5 20 MEMO Return to Library...
Page 82: ...6 8 Machine body Fig 6 1 Lifting the Machine Return to Library...
Page 96: ...7 4 MEMO Return to Library...