CONNECT DRYER
TO EXHAUST
SYSTEM
Secure all joints with clamps or duct
tape. DO NOT use sheet metal
screws or other fastening means
which extend into the duct to attach
exhaust pipe joints. They could
catch lint and reduce the efficiency
of the exhaust system.
IMPORTANT:
Keep exhaust duct
as short as possible.
Be sure old ducts are clean before
installing your new dryer.
To prevent backdraft when dryer is
not in operation, outer end of
exhaust pipe must have a weather
hood with hinged dampers (obtain
locally).
Weather hood should be installed at
least 12" (30.5 cm) above the
ground. Higher clearances may be
necessary in areas where heavy
snowfall can occur.
No extra system length considera-
tion is necessary when exhausting
through the roof. Use MAXIMUM
EXHAUST LENGTH table to
calculate system length. Use a roof
cap that provides air flow equal to
weather hood.
Exhaust Directions
Dryer can be exhausted to the out-
doors through the back, left, right or
bottom of the dryer.
Dryer is shipped from factory ready
for rear exhaust. No kits required.
To exhaust dryer through sides or
bottom, install a DK1 Sales
Accessory (Directional Exhaust Kit
528P3). Available as optional equip-
ment at extra cost.
Exhaust System Materials
Exhaust duct must be four inches
(10.2 cm) in diameter without
obstructions. Rigid metal duct is
recommended. Non-combustible
semi-rigid flexible metal duct is
acceptable.
DO NOT use plastic pipe, foil pipe,
or flexible plastic pipe, because it
contributes to poor drying perform-
ance and collects lint, which can
lead to a fire hazard. To identify
flexible foil or plastic duct, pinch the
coils of the duct between your fin-
gers. If the coils can be brought
together, do not use the duct.
Do Not Use
Use
Rigid Metal
Semirigid Metal
Plastic
Flexible Foil
Maximum Exhaust Length
Rigid Metal Duct
Number of
Weather Hood
Weather Hood
90° Elbows
4-inch Opening
2
1
⁄
2
-inch Opening
0
44 feet (13.4 m)
34 feet (10.4 m)
1
34 feet (10.4 m)
26 feet (7.9 m)
2
26 feet (7.9 m)
20 feet (6.1 m)
3
20 feet (6.1 m)
14 feet (4.3 m)
Flexible Metal Duct
Number of
Weather Hood
Weather Hood
90° Elbows
4-inch Opening
2
1
⁄
2
-inch Opening
0
24 feet (7.3 m)
20 feet (6.1 m)
1
20 feet (6.1 m)
16 feet (4.9 m)
2
16 feet (4.9 m)
12 feet (3.7 m)
3
12 feet (3.7 m)
8 feet (2.4 m)
4" (10,16 cm)
4" (10,16 cm)
2-1/2" (6,35 cm)
Recommended Weather Hood
Recommended for
Short Runs Only
Summary of Contents for NDE2335AY Series
Page 9: ...2006 Maytag Services 16026315 7 Important Safety Information...
Page 27: ...2006 Maytag Services 16026315 A 1 AppendixA...
Page 28: ...A 2 16026315 2006 Maytag Services NOTES...
Page 42: ...B 2 16026315 2006 Maytag Services...
Page 44: ...B 4 16026315 2006 Maytag Services 1...
Page 45: ...2006 Maytag Services 16026315 B 5 2...
Page 46: ...B 6 16026315 2006 Maytag Services 3...
Page 47: ...2006 Maytag Services 16026315 B 7 4...
Page 48: ...B 8 16026315 2006 Maytag Services 5...
Page 49: ...2006 Maytag Services 16026315 B 9 6...
Page 50: ...B 10 16026315 2006 Maytag Services 7...
Page 51: ...2006 Maytag Services 16026315 B 11 8...
Page 52: ...B 12 16026315 2006 Maytag Services 9...
Page 53: ...2006 Maytag Services 16026315 B 13 10...
Page 54: ...B 14 16026315 2006 Maytag Services 11...
Page 55: ...2006 Maytag Services 16026315 B 15 12...
Page 56: ...B 16 16026315 2006 Maytag Services 13...
Page 57: ...2006 Maytag Services 16026315 B 17 14...
Page 58: ...B 18 16026315 2006 Maytag Services...
Page 60: ...B 20 16026315 2006 Maytag Services 1...
Page 61: ...2006 Maytag Services 16026315 B 21 2...
Page 62: ...B 22 16026315 2006 Maytag Services 3...
Page 63: ...2006 Maytag Services 16026315 B 23 4...
Page 64: ...B 24 16026315 2006 Maytag Services 5...
Page 65: ...2006 Maytag Services 16026315 B 25 6...
Page 66: ...B 26 16026315 2006 Maytag Services 7...
Page 67: ...2006 Maytag Services 16026315 B 27 8...
Page 68: ...B 28 16026315 2006 Maytag Services 9...
Page 69: ...2006 Maytag Services 16026315 B 29 10...
Page 70: ...B 30 16026315 2006 Maytag Services 11...
Page 71: ...2006 Maytag Services 16026315 B 31 12...
Page 72: ...B 32 16026315 2006 Maytag Services...
Page 74: ...B 34 16026315 2006 Maytag Services 1...
Page 75: ...2006 Maytag Services 16026315 B 35 2...
Page 76: ...B 36 16026315 2006 Maytag Services 3...
Page 77: ...2006 Maytag Services 16026315 B 37 4...
Page 78: ...B 38 16026315 2006 Maytag Services 5...
Page 79: ...2006 Maytag Services 16026315 B 39 6...
Page 80: ...B 40 16026315 2006 Maytag Services 7...
Page 81: ...2006 Maytag Services 16026315 B 41 8...
Page 82: ...B 42 16026315 2006 Maytag Services 9...