INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Parts supplied

Check that all parts are included. 

Bag containing literature.

Conversion orifice spuds (inside bag containing literature).

Anti-tip brackets must be securely mounted to subfloor. 
Thickness of flooring may require longer screws to anchor 
bracket to subfloor. Longer screws are available from your 
local hardware store.

Parts needed

Check local codes and consult gas supplier. Check existing gas 
supply and electrical supply. See “Electrical Requirements” and 
“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do 
not obstruct flow of combustion and ventilation air. 

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the oven frame behind 
the left side of the broiler door.

The range should be located for convenient use in the kitchen.

Recessed installations must provide complete enclosure of 
the sides and rear of the range.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

All openings in the wall or floor where range is to be installed 
must be sealed.

Do not seal the range to the side cabinets.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip 
Bracket” section.

Grounded electrical supply is required. See “Electrical 
Requirements” section. 

Proper gas supply connection must be available. See “Gas 
Supply Requirements” section.

Contact a qualified floor covering installer to check that the 
floor covering can withstand at least 200°F (93°C). 

Use an insulated pad or ¼" (0.64 cm) plywood under range if 
installing range over carpeting.

IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This oven 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194°F (90°C).

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

Level

³⁄₈

" drive ratchet

Tape measure

Flat-blade screwdriver

Phillips screwdriver

Hand or electric drill

Wrench or pliers

7 mm combination wrench

Pipe wrench

¹⁄₈

" (3.2 mm) drill bit (for wood floors)

³⁄₁₆

" (4.8 mm) carbide-tipped masonry drill bit (for concrete/

ceramic floors)

Pipe-joint compound resistant to LP gas

Noncorrosive leak-detection solution

A. Anti-tip bracket
B. Plastic anchors (2)

C. #10 x 

¹⁄₂

" screws (2)

B

A

C

Summary of Contents for MGR5605W

Page 1: ...SITOS DE INSTALACI N 16 Piezas y herramientas 16 Requisitos de ubicaci n 16 Requisitos el ctricos 18 Requisitos del suministro de gas 18 INSTRUCCIONES DE INSTALACI N 20 Desempaque la estufa 20 Instala...

Page 2: ...ath Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any ele...

Page 3: ...enings in the wall or floor where range is to be installed must be sealed Do not seal the range to the side cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum...

Page 4: ...mm minimum IMPORTANT If installing a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances...

Page 5: ...ional Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the range must be conducted according to the manufacturer s instructions Type of Gas Natural gas...

Page 6: ...be at least 1 water column pressure above the manifold pressure shown on the model serial rating plate Line pressure testing above psi gauge 14 WCP The range and its individual shutoff valve must be...

Page 7: ...e anti tip bracket with the screws provided Depending on the thickness of your flooring longer screws may be necessary to anchor the bracket to the subfloor Longer screws are available from your local...

Page 8: ...y brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found 5 Close the broiler door 6 Place burners burner caps and grates on the cooktop A Pressure...

Page 9: ...setting a hot surface igniter heats to a bright orange and ignites the gas No sparking occurs The glow bar remains on while the burner operates Check Operation of Cooktop Burners 1 If control panel an...

Page 10: ...k blue and should be clean and soft in character No yellow tips not enough air blowing or lifting too much air of flame should occur If the flame needs adjusting 1 Turn the oven off Wait for the oven...

Page 11: ...burner grate burner caps and burners A To range B Manual shutoff valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut o...

Page 12: ...tall the number 56 LP gas spud IMPORTANT Do not over tighten 6 Place Natural gas oven burner spud in plastic parts bag along with Natural gas cooktop burner spuds for future use and keep with the bag...

Page 13: ...for top burners in the literature bag included with the range Three Natural gas spuds are stamped 149 and one 165 3 Remove the LP gas orifice spuds using a 7 mm combination wrench 4 Install the Natur...

Page 14: ...7 Reinstall oven burner 8 Reinstall oven racks oven tray and flame spreader Complete Conversion 1 Refer to the Make Gas Connection section for properly connecting the range to the gas supply 2 Turn t...

Page 15: ...n en este manual debe ser observada para minimizar el riesgo de incendio o explosi n o para prevenir da os a propiedades heridas o la muerte No almacene o use gasolina u otros l quidos y vapores infla...

Page 16: ...un recinto cerrado de los lados y la parte posterior de la estufa Para eliminar el riesgo de quemaduras o incendio al tocar unidades con la superficie demasiado caliente deber evitarse el uso de armar...

Page 17: ...rodantes necesitan Cuando se instale la estufa en una casa rodante deber asegurarse al piso durante el transporte Cualquier m todo de fijaci n es adecuado en tanto cumpla con las normas indicadas arri...

Page 18: ...s los c digos y reglamentos aplicables IMPORTANTE Esta instalaci n debe hacerse de acuerdo con todos los c digos y ordenanzas locales Si no hay c digos locales la instalaci n deber hacerse de acuerdo...

Page 19: ...vula de cierre La v lvula es para abrir o cerrar el suministro de gas a la estufa Regulador de la presi n de gas Deber usarse el regulador de la presi n de gas suministrado con esta estufa Para el fun...

Page 20: ...ue la estufa de pie nuevamente sobre el cart n o madera Instalaci n del soporte anti vuelco P ngase en contacto con un instalador competente de revestimiento de pisos para ver cu l es el mejor procedi...

Page 21: ...e anti vuelco 12 Si instala la estufa en una casa rodante deber fijar la estufa al piso Cualquier m todo de fijaci n es adecuado en tanto cumpla con las normas indicadas en la secci n Requisitos de ub...

Page 22: ...una casa rodante deber fijar la estufa al piso Cualquier m todo de fijaci n es adecuado en tanto cumpla con las normas indicadas en la secci n Requisitos de ubicaci n 3 Contin e instalando la estufa...

Page 23: ...ener la llama m s peque a que no se apague cuando se gire el control de un quemador fr o de HI Alto a Lo Bajo Gire hacia la derecha para reducir la altura de la llama Gire hacia la izquierda para aume...

Page 24: ...a instalar las parrillas del horno y cierre la puerta del mismo 9 Cierre la puerta del asador Complete la instalaci n 1 Revise para cerciorarse de que todas las piezas est n instaladas Si hay alguna p...

Page 25: ...de gas nueva con aprobaci n de CSA International Instale una v lvula de cierre Apriete firmemente todas las conexiones de gas Si se conecta a un suministro de gas LP la presi n no debe exceder una col...

Page 26: ...s de los mismos C mo convertir el quemador del horno 1 Abra la puerta del horno y saque las parrillas charola y esparcidor de llama del horno d jelos a un lado 2 Levante el quemador del horno La espit...

Page 27: ...1 Gire la v lvula de cierre manual a la posici n de cerrado 2 Desenchufe la estufa o desconecte el suministro de energ a 3 Abra la puerta del asador y saque la charola para asar El regulador de la pre...

Page 28: ...apriete demasiado 6 Coloque la espita del quemador del horno de gas L P en la bolsa de piezas junto con las espitas del quemador de la superficie de cocci n de gas L P para usarlas en el futuro y gua...

Reviews: