Maytag MGDZ600TK - Front Load Gas Dryer Install Manual Download Page 11

11

Optional exhaust installations

Exhaust Cover Kit (to cover unused exhaust holes):

Part Number W10186596 - all models

This dryer can be converted to exhaust out the right side, left side or 
through the bottom. If you prefer, you may contact your local dealer 
to have the dryer converted.

A

B

C

A. Standard rear offset exhaust installation
B. Left or right side exhaust installation

C. Bottom exhaust installation

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best 

 

for your installation. Two close-clearance installations are shown. 
Refer to the manufacturer’s instructions. 

A

B

A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation

NOTE:

 The following kits for close clearance alternate installations 

are available for purchase. Please see the “Assistance or Service” 
section to order.

Over-the-Top Installation: 

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent 
mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch

Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) 
mismatch

Special provisions for mo

b

ile home installations

The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct 
path outdoors. 

Plan the installation to use the fewest number of elbows 

 

and turns. 

When using elbows or making turns, allow as much room 

 

as possible. 

Bend vent gradually to avoid kinking. 

Use the fewest 90° turns possible.

Determine vent length and el

b

ows needed for 

b

est 

drying performance

Use the following Vent system chart to determine type of vent 
material and hood combinations acceptable to use.

NOTE:

 Do not use vent runs longer than those specified in the 

Vent system chart. 

Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and 
increased energy usage.

The Vent system chart provides venting requirements that will help 
to achieve the best drying performance.

Vent system chart

NOTE: 

Side and bottom exhaust installations have a 90º turn inside 

the dryer. To determine maximum exhaust length, add one 90º turn 
to the chart.

Bends or

 

90º el

b

ows

Type of vent

Box or Louvered 

 

hoods

Angled hoods

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

1

Rigid metal

54 ft (16.5 m) 

48 ft (14.6 m)

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

Summary of Contents for MGDZ600TK - Front Load Gas Dryer

Page 1: ...14 Dryer Results 15 TABLE DES MATI RES S CURIT DE LA S CHEUSE 16 EXIGENCES D INSTALLATION 18 Outillage et pi ces 18 quipement facultatif 18 Exigences d emplacement 18 RACCORDEMENT DE L ALIMENTATION L...

Page 2: ...nstructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safet...

Page 3: ...e detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smel...

Page 4: ...ut the accessories available for your dryer Location Requirements You will need A location that allows for proper exhaust installation See Venting Requirements A separate 30 amp circuit If you are usi...

Page 5: ...of the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered Custom undercounter installation Dryer only 2 50 mm 36...

Page 6: ...anufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or Standard CAN CSA Z240 MH Mobile...

Page 7: ...of dryer s final location 4 wire receptacle 14 30R If using a replacement power supply cord it is recommended that you use Power Supply Cord Replacement Part Number 9831317 For further information pl...

Page 8: ...fitting If your dryer has been converted to use LP gas 3 8 LP compatible copper tubing can be used If the total length of the supply line is more than 20 ft 6 1 m use larger pipe NOTE Pipe joint comp...

Page 9: ...nt according to the supply line type size and location A 3 8 flexible gas connector B 3 8 dryer pipe C 3 8 to 3 8 pipe elbow D 3 8 pipe to flare adapter fitting A B C D 3 Open the shutoff valve in the...

Page 10: ...ows Good Better Clamps Use clamps to seal all joints Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint Do no...

Page 11: ...securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select the route that w...

Page 12: ...102 mm clamp 2 Move dryer into its final location Do not crush or kink vent 3 On gas models Check that there are no kinks in the flexible gas line 4 Once the exhaust vent connection is made remove the...

Page 13: ...80 180 Reverse hinge 1 Use a small flat blade screwdriver to remove 2 plug strips from the inner door Slide the head of the screwdriver under the plugs being certain not to scratch the inner door surf...

Page 14: ...lectrician Was a regular fuse used Use a time delay fuse No heat Has a household fuse blown or has a circuit breaker tripped The drum may be turning but you may not have heat Electric dryers use 2 hou...

Page 15: ...l or flexible metal vent See the Installation Instructions Are fabric softener sheets blocking the grille Use only one fabric softener sheet and use it only once Is the exhaust vent the correct length...

Page 16: ...de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous...

Page 17: ...d installation B149 1 du gaz naturel ou du propane La s cheuse doit tre lectriquement reli e la terre conform ment aux codes locaux ou en l absence de codes locaux au Code canadien de l lectricit CSA...

Page 18: ...voir plus sur les accessoires disponibles pour votre s cheuse Exigences d emplacement Il vous faudra Un emplacement avec un conduit d vacuation proximit Voir Exigences concernant l vacuation Un circui...

Page 19: ...n de r duire le transfert de bruit Pour installation dans un placard avec porte on doit pr voir des ouvertures minimales d entr e d air en haut et en bas de la porte Les portes claire voie offrant des...

Page 20: ...cement requis Exigences suppl mentaires concernant l installation dans une maison mobile Cette s cheuse peut tre install e dans une maison mobile L installation doit tre conforme la norme canadienne s...

Page 21: ...4 30R En cas d utilisation d un cordon d alimentation de rechange il est recommand d utiliser le cordon d alimentation lectrique num ro 9831317 pi ce de rechange Pour en savoir plus veuillez vous repo...

Page 22: ...tion en gaz de la s cheuse voir l illustration suivante Un tuyau IPS de 1 2 est recommand Pour les longueurs inf rieures 20 pi 6 1 m on peut utiliser des tuyaux approuv s de cuivre ou d aluminium de 3...

Page 23: ...r un compos d tanch it des tuyauteries r sistant l action du gaz de p trole liqu fi Ne pas utiliser de ruban TEFLON TEFLON est une marque d pos e de E I Du Pont De Nemours et Compagnie On doit utilise...

Page 24: ...et soutenu lorsque la s cheuse est sa position finale Enlever tout exc s de conduit souple pour viter tout affaissement ou d formation susceptible de r duire la capacit d vacuation et le rendement Ne...

Page 25: ...tion au dessus de la s cheuse galement disponible avec un coude d cal B Installation avec p riscope REMARQUE On peut acheter les trousses suivantes pour les installations o le d gagement est r duit Vo...

Page 26: ...me d vacuation viter les changements de direction 90 Utiliser des brides de serrage pour sceller tous les joints Ne pas utiliser de ruban adh sif pour conduit de vis ou d autres dispositifs de fixatio...

Page 27: ...ec s chage chaud et mettre la s cheuse en marche Ne pas s lectionner le r glage Air Only air seulement Si la s cheuse ne d marre pas v rifier ce qui suit Les commandes sont r gl es la position de marc...

Page 28: ...partie interne de la porte doit se trouver compl tement l int rieur du bord de la partie externe de la porte 6 Assembler de nouveau les parties interne et externe de la porte avec les 6 vis Inversion...

Page 29: ...nner un programme de s chage minut avec chaleur et remettre la s cheuse en marche Si le message reste affich consulter un lectricien qualifi Codes de service variables F F1 E1 F3 E1 etc Faire un appel...

Page 30: ...rogrammes de la s cheuse exige des temp ratures sup rieures 45 F 7 C La s cheuse est elle install e dans un placard Les portes du placard doivent comporter des ouvertures d a ration au sommet et en ba...

Page 31: ...31 NOTES...

Page 32: ...W10261613A W10267630A SP 2009 Whirlpool Corporation All rights reserved 11 09 Printed in U S A...

Reviews: