Consider

Location

Description

Use dimensions shown in manual to determine space needed for installation.

Place dryer on a solid floor in an area with an adequate air supply. A closet door
must have a supply air vent of 80 sq. in. (517 sq. cm) minimum.

No other fuel burning appliance should be installed in the same closet with the dryer.

Dryer must not be installed or stored in an area where it will be exposed to water
and/or weather.

Manufactured (mobile) home installation must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 32-80 or Standard
CAN/CSA-Z240 MH.

Gas dryers must be permanently attached to the floor at the time of installation.
Order No. 526P3 Dryer Installation Kit for a manufactured (mobile) home installation.

Dryer requires 120 volt, 15 amp, 60 Hz power supply and 3-prong grounding plug.
Power cord is approximately 69" long. Do not operate other appliances on the same
circuit when this appliance is operating. Refer to serial plate for specific require-
ments. Wiring diagram is located in control hood.

Electrical Requirements

Natural Gas Pressure, 1000 Btu/ ft

3

(37.3 MJ/m

3

), service must be supplied at 6.5 +

1.5 inch water column pressure. L.P. (propane) Gas Pressure, 2,500 Btu/ ft

3

(93.1

MJ/m

3

), service must be supplied at 10 + 1.5 inch water column pressure.

NOTE: The dryer and its appliance main gas valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psi (3.45 kPa). Dryer must be isolated from the gas supply piping
system by closing the equipment shut-off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than 1/2 psi (3,45 kPa).

When connecting to a gas line, an equipment shutoff valve must be installed within
6' (1.8 m) of the dryer. An 1/8" N.P.T. pipe plug must be installed.

The gas service to a gas dryer must conform with the local codes and ordances or in
the absence of local codes and ordinances, with the latest edition of the National
Fuel Gas Code ANSIZ223.1/NFPA 54 or the CAN/CGA-B149, National Gas
Installation Code. LPK1 Sales Accessory (L.P./Propane Gas Conversion Kit 649P3)
must be installed. DO NOT connect dryer to L.P./Propane Gas Service without
converting the gas valve.

Gas

Use rigid or semi-rigid duct and exhaust the dryer to the outside by the shortest
route possible. Failure to exhaust dryer properly will void warranty.

• Dryer exhaust duct must be secured to the mobile home structure. Dryer exhaust

MUST NOT terminate under the mobile home.

• Exhaust duct must not be connected to any other duct, vent or chimney.

• Venting materials are not supplied with the dryer (obtain locally). Do not use plas-

tic or thin foil flexible ducting.

• Static pressure in the dryer’s exhaust duct should be no greater than .6 inches (1.5

cm). Check with dryer running and no load. This can be measured with a manome-
ter placed on the exhaust duct approximately two feet (61 cm) from the dryer.

For the best exhaust system:

• Locate dryer so exhaust duct is as short as possible.

• Verify old ducts are cleaned before installing new dryer.

• Use 4 inch (10.2 cm) diameter rigid or flexible metal duct.

• Use duct tape on all joints.

• Use as few elbows as possible.

Exhaust

Installation Requirements

Before You Install…

Summary of Contents for MDG2706AWW

Page 1: ...ble at extra cost through your Maytag dealer or Maytag Customer Assistance at 1 800 688 9900 USA 1 800 688 2002 Canada 1 800 688 2080 TTY USA Only Directional Exhaust Kit DK1 Sales Accessory Direction...

Page 2: ...aust No kits required To exhaust dryer through sides or bottom install a DK1 Sales Accessory Directional Exhaust Kit 528P3 Available as optional equip ment at extra cost Exhaust System Materials Exhau...

Page 3: ...of gas as shown on nameplate located in the door recess For proper operation at altitudes above 2 500 feet The natural gas valve spud orifice size must be reduced to ensure complete combustion See tab...

Page 4: ...ny other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neig...

Page 5: ...ply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 45 kPa When connecting to a gas...

Page 6: ...ith front access panel removed WARNING To prevent personal injury or property damage front panel must be in place during normal operation Close the loading door start the dryer in a heat setting refer...

Page 7: ...ur Ensembles facultatifs Ensembles disponibles contre factura tion additionnelle consulter le d tail lant Maytag ou le service la client le de Maytag au 1 800 688 9900 U 1 800 688 2002 Canada 1 800 68...

Page 8: ...Pour l vacuation par le c t ou par le bas installer l ensemble accessoire DK1 ensemble pour vacuation directionnelle n 528P3 disponible raison d un co t sup pl mentaire comme quipement facultatif Mat...

Page 9: ...ssurer l tanch it sur chaque join ture de tuyauterie utiliser du ruban de Pour un fonctionnement correct une altitude sup rieure 762 m 2 500 pi Pour garantir une combustion compl te du gaz on doit r d...

Page 10: ...de tout autre appareil QUE FAIRE SI L ON SENT UNE ODEUR DE GAZ Ne mettre aucun appareil en marche Ne pas toucher un interrupteur lectrique n utiliser aucun t l phone de l immeuble Se rendre chez un v...

Page 11: ...ns le cas du raccordement de l appareil une canalisation de gaz on doit installer un robinet d arr t moins de 1 8 m 6 pi de la s cheuse On doit galement incorporer dans la canalisation un raccord ferm...

Page 12: ...ommages mat riels on doit laisser le panneau avant en place durant le fonctionnement normal Fermer la porte de chargement faire fonction ner la s cheuse avec chauffage voir le guide de l utilisateur L...

Page 13: ...uidor Maytag o del Departamento de Ayuda a los Consumidores Maytag Customer Assistance llamando al 1 800 688 9900 EE UU 1 800 688 2002 Canad 1 800 688 2080 Personas con problemas auditivos o del habla...

Page 14: ...dor La secadora es enviada desde la f brica lista para evacuaci n por la parte trasera No se necesitan kits especiales Para evacuar la secadora a trav s de los costados o por la parte inferior instale...

Page 15: ...spu s de que haya conectado el suministro de gas Ver la secci n Verificaci n de la Llama del Quemador en la ltima p gina La secadora debe ser conectada al tipo de gas que se indica en la placa de dato...

Page 16: ...GAS NO trate de encender ning n artefacto el ctrico NO toque ning n interruptor el ctrico NO use ning n tel fono en su edificio Llame inmediatamente a su proveedor de gas desde el tel fono de un veci...

Page 17: ...rando la v lvula de cierre del equipo durante cualquier prueba de la presi n de la tuber a de sumi nistro del gas a presiones de prueba iguales o inferiores a 1 2 libra pulg2 3 45 kPa Cuando se conect...

Page 18: ...cceso delantero ADVERTENCIA Para evitar una lesi n personal o da os materiales el panel delantero debe estar colocado en su lugar durante el funcionamiento normal de la secadora Cierre la puerta de ca...

Page 19: ...19 Notes...

Page 20: ...Part No 40136401 Printed in U S A 11 01 MAYTAG 403 West Fourth Street North P O Box 39 Newton Iowa 50208...

Reviews: