Microwave Power Test Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
16023053 Rev. 0
©2004 Maytag Appliances Company
18
Power Test (Traditional 1 Liter Test)
Test equipment required is Amana power test kit R0157397 (Fahrenheit), or Menumaster power test kit M95D5
(Celsius).
1. Fill the plastic container to the bottom of the 1000 ml. line with cool tap water.
2. Using the thermometer; Fahrenheit or Celsius, stir the water, measure and record the water temperature.
Initial water temperature should be approximately 60
°
F.
3. Place container on the center of the oven shelf and heat the water for 63 seconds.
NOTE:
Use a watch second hand, not the oven timer.
4. Stir the water, measure and record the temperature of the water after heating time is complete.
5. Subtract the starting water temperature (Step 2), from the ending water temperature (Step 4) to obtain the
temperature rise.
6. See the Temperature Chart provided below.
NOTE:
Always perform power test three times for accuracy, changing the water after each test is performed.
NOTE:
Variation or errors in the test procedure will cause a variance in the temperature rise indication. Additional
power tests should be made if temperature rise appears marginal.
NOTE:
Low line voltage may cause lower power output (temperature rise).
Temperature Chart
SIXTY
−
THREE SECONDS run time chart for units less than 1550 Watts cooking power
∆
T Cooking
∆
T Cooking
∆
T Cooking
∆
T Cooking
(°F)
Power Output
(°F) Power Output
(°C)
Power Output
(°C)
Power Output
12
464
27
1046
7
490
15
1050
13
504
28
1085
8
560
16
1120
14
542
29
1124
9
630
17
1190
15
581
30
1162
10
700
18
1260
16
620
31
1201
11
770
19
1330
17
659
32
1240
12
840
20
1400
18
697
33
1279
13
910
21
1470
19
736
34
1317
14
980
20
775
35
1359
21
814
36
1395
22
852
37
1434
23
891
38
1472
24
930
39
1511
25
969
40
1550
26
1007