C–4
16023522
©2004 Maytag Services
Conversion Instructions
(Models CPL1100AD*, CGL1100AD*)
-9-
GAS CONVERSION
General
All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it was adjusted for at the
factory. To convert the unit to either Natural gas or LP gas
will require the replacement of orifice hoods, adjustment
of the air shutters on the burners and adjustment of the
appliance pressure regulator converter cap.
SEE INSTRUCTIONS FOR GAS CONVERSION
LOCATED ON THE BACK OF THE RANGE.
Inlet pressure to the appliance pressure regulator should
be as follows for both operation and checking of appliance
pressure regulator setting:
INLET PRESSURE IN
NATURAL
LP
INCHES OF WATER COLUMN
GAS
GAS
Minimum
5
11
Maximum
14
14
HOW TO REMOVE RANGE
FOR SERVICING
Follow these procedures to remove appliance for
servicing:
1. Shut off gas supply to appliance.
2. Disconnect electrical supply to appliance, if equipped.
3. Disconnect gas supply tubing to appliance.
4. Slide range forward to disengage range from the
anti-tip bracket. (See page 4).
5. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection.
NOTE:
A qualified servicer should disconnect and
reconnect the gas supply.
The servicer
MUST
follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
6. To prevent range from accidentally tipping, range must
be secured to the floor by sliding rear leveling leg into
the anti-tip bracket.
SERVICE - PARTS INFORMATION
WHEN YOUR RANGE REQUIRES SERVICE OR
REPLACEMENT PARTS, CONTACT YOUR DEALER
OR AUTHORIZED SERVICE AGENCY. PLEASE GIVE
THE COMPLETE MODEL AND SERIAL NUMBERS OF
THE RANGE WHICH IS LOCATED ON THE RANGE
MODEL NUMBER PLATE.
Summary of Contents for CG31400ADW
Page 26: ...A 1 16023522 2004 Maytag Services Appendix A ...
Page 27: ... 2004 Maytag Services 16023522 A 2 Installation Instructions Models CP31200AD CG31200AD 2 ...
Page 38: ...B 1 16023522 2004 Maytag Services Appendix B ...
Page 39: ... 2004 Maytag Services 16023522 B 2 Use Instructions Models CP CG31200AD CPL1100AD CGL1100AD ...
Page 40: ...B 3 16023522 2004 Maytag Services Use Instructions Models CP CG31200AD CPL1100AD CGL1100AD ...