Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.
14
16023522
©2004 Maytag Services
Illustration Component
Test
Procedure
Results
Oven light socket
Test continuity of receptacle terminals ...
Measure voltage at oven light.................
Indicates continuity with bulb inserted.
120 VAC, see wiring diagram for terminal
identification.
If no voltage present, check wiring.
Rocker switch
Measure continuity of switch positions:
Closed.................................................
Open ...................................................
Continuity
Infinite
COM
NO
NC
Door lock switch
Switch connection in following
positions: Not
engaged ........................
Engaged ..............................
Normally Open
COM-NO=Open, COM-NC=Closed
COM-NO=Closed, COM-NC=Open
Manual Latch
assembly with switch
Disconnect wires and test for
continuity per wiring diagram ..................
See wiring diagram for schematic layout.
Refer to Parts Manual for replacement
components.
NOTE:
Control will cancel function if
latch is moved to LOCK position during
Bake or Broil.
Bake burner
Verify gas is supplied.
Verify proper orifice installed-Nat or LP ..
Check for obstructions, contamination
in ports or damage .................................
Air shutter opening: .469" to .531".
Blue flame with no yellow tipping.
Replace if punctured or torn.
Bake burner
Models CPL1100AD*,
CGL1100AD*
Verify gas is supplied.
Verify proper orifice installed-Nat or LP ..
Check for obstructions, contamination
in ports or damage .................................
Air shutter opening: .349" to .411".
Blue flame with no yellow tipping.
Replace if punctured or torn.
Broil burner
Verify gas is supplied.
Verify proper orifice installed-Nat or LP ..
Check for obstructions, contamination
in ports or damage .................................
Air shutter opening: .281" to .343".
Blue flame with no yellow tipping.
Replace if punctured or torn.
Ignitor
Test for voltage at terminals ...................
Test for amount of amperage in circuit ...
(Ignitor may glow, but not have
sufficient amperage to open valve).
120 VAC
3.2 to 3.6 Amps.
Temperature sensor
Measure resistance ................................ Approximately 1000
Ω
at room
temperature 80
°
F.
Gas thermostat
Models AGR4400AD*,
CGR1415AD*,
CGR1110AD*,
CGL1100AD*,
CPL1100AD*,
CP31200AD*,
CG31200AD*,
CG31400AD*
Test for voltage at terminals ................... 120 VAC
Gas thermostat
Model CPR1100AD*
Test for voltage at terminals ................... 120 VAC
Pressure regulator
Verify gas pressure (WCP).....................
If using LP service, verify proper gas
supply conversion.
4
"
Natural
10
"
LP/Propane
Spark ignition
electrode
Test for resistance of spark lead ............
Test ignitor to chassis.............................
Continuity
No continuity from ignitor to chassis.
Summary of Contents for CG31400ADW
Page 26: ...A 1 16023522 2004 Maytag Services Appendix A ...
Page 27: ... 2004 Maytag Services 16023522 A 2 Installation Instructions Models CP31200AD CG31200AD 2 ...
Page 38: ...B 1 16023522 2004 Maytag Services Appendix B ...
Page 39: ... 2004 Maytag Services 16023522 B 2 Use Instructions Models CP CG31200AD CPL1100AD CGL1100AD ...
Page 40: ...B 3 16023522 2004 Maytag Services Use Instructions Models CP CG31200AD CPL1100AD CGL1100AD ...
Page 49: ... 2004 Maytag Services 16023522 C 1 Appendix C ...