Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.
18
16023522
©2004 Maytag Services
Diagnostic Code Checking
Code Description
When
Checked
Detection
1c1c
Shorted key
Always
1 minute
1c2c
Keyboard tail disconnected
Always
1 minute
1c31
Cancel key circuit problem
Always
20 seconds
1c6c
EEPROM error
When accessing EEPROM
3 tries
1c7c
Control not calibrated
Always
3 tries
1c8c
Cooking program error
Cook or clean programmed
3 tries
1d11
Runaway temp (650
°
F), door unlocked
Latch unlocked
1 minute
1d21
Runaway temp (950
°
F), door locked
Latch locked
1 minute
3d11
Sensor open
Cook or clean active
20 seconds
3d21
Sensor shorted
Cook or clean active
20 seconds
9d11
Latch will not lock
Latch should be locked
See Note 6
Diagnostic Code Handling
Code
Measurable
What is Displayed
Action Taken By Control
1c1c Keypress
Nothing
Disables audible for affected key
depression
Disables all outputs
1, 2
Disables lights and timers
1c2c
Keyboard loop improper value
Nothing
Disables audible for key depression
Disables all outputs
1
Disables lights and timers
1c31
Cancel key improper value
BAKE flashes
3
Disables all outputs for cavity
1
1c6c
No response from EEPROM
Nothing
Disables all outputs
1
1c7c
Calibration value out of range
"CAL" in the time digits
Completely disables oven
4
1c8c
CRC invalid
Nothing
Cancels active cook function
1d11
Sensor resistance > 2237 Ohms
BAKE flashes
3
Disables all cook function for cavity
1d21
Sensor resistance > 2787 Ohms
BAKE flashes
3
Disables all cook function for cavity
3d11
Sensor resistance > Infinite Ohms
BAKE flashes
3
Disables all cook function for cavity
3d21
Sensor resistance > 0 Ohms
BAKE flashes
3
Disables all cook function for cavity
4d11
Door switch not closed when door is
locked
Nothing
Disables Clean and Lockout
functions 5
4d51
Door switch not open or closed
Nothing
Disables Clean and Lockout
functions 4, 5
Turn off light and disable light from
door switch
9d11
Lock switch not closed
LOCK flashes
3
Disables Clean and Lockout
functions
4
Summary of Contents for CG31400ADW
Page 26: ...A 1 16023522 2004 Maytag Services Appendix A ...
Page 27: ... 2004 Maytag Services 16023522 A 2 Installation Instructions Models CP31200AD CG31200AD 2 ...
Page 38: ...B 1 16023522 2004 Maytag Services Appendix B ...
Page 39: ... 2004 Maytag Services 16023522 B 2 Use Instructions Models CP CG31200AD CPL1100AD CGL1100AD ...
Page 40: ...B 3 16023522 2004 Maytag Services Use Instructions Models CP CG31200AD CPL1100AD CGL1100AD ...
Page 49: ... 2004 Maytag Services 16023522 C 1 Appendix C ...