Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge the high voltage
capacitor before servicing, unless testing requires power.
©2004 Maytag Services
16023056 Rev. 0
19
Illustration Component
Test
Procedure
Results
Power Level
Cycle On
(Continuity)
Cycle Off
(Open)
1
4 sec
18 sec
2
6 sec
16 sec
3
8 sec
14 sec
4
10 sec
12 sec
5
12 sec
10 sec
6
14 sec
8 sec
7
16 sec
6 sec
8
18 sec
4 sec
9
20 sec
2 sec
AMV4204A**,
MMV4205A**,
AMV5164A**,
MMV5165A**,
AMV5206A**,
MMV5207A**,
JMV8208A**
Relay 7
Disconnect the leads. Place water in the
oven and select power levels 1 through
10. Check continuity between the
terminals of the relays.
10
22 sec
0 sec
AMV4204A**,
MMV4205A**,
MMV5165A**,
AMV5206A**,
MMV5207A**,
JMV8208A**
Primary Interlock
Switch Test
(Top Switch)
1
2
Measure resistance between
terminals 1 and 2:
Door Open ...............................................
Door Closed.............................................
Open
Continuity
UMV1152B**,
MMV1153A**,
AMV1162A**,
AMV5164A**
Primary Interlock
Switch Test
(Bottom Switch)
1
2
Measure resistance between
terminals 1 and 2:
Door Open ...............................................
Door Closed.............................................
Open
Continuity
AMV4204A**,
MMV4205A**,
MMV5165A**,
AMV5206A**,
MMV5207A**,
JMV8208A**
Secondary Interlock
Switch Test
(Bottom Switch)
Measure resistance between
terminals 1 and 2:
Door Open ...............................................
Door Closed.............................................
Open
Continuity
UMV1152B**,
MMV1153A**,
AMV1162A**,
AMV5164A**
Secondary Interlock
Switch Test
(Top Switch)
Measure resistance between
terminals 1 and 2:
Door Open ...............................................
Door Closed.............................................
Open
Continuity
All Models
Interlock Monitor
Switch Test
(Middle Switch)
1
2
Measure resistance between
terminals 1 and 2:
Door Open ...............................................
Door Closed.............................................
Continuity
Open
Summary of Contents for AMV1162AAB/W/Q/S
Page 9: ... 2004 Maytag Services 16023056 Rev 0 9 General Information Microwave Oven Description ...
Page 41: ... 2004 Maytag Services 16023056 Rev 0 A 1 Appendix A ...
Page 42: ...A 2 16023056 Rev 0 2004 Maytag Services Installation Instructions ...
Page 46: ...A 6 16023056 Rev 0 2004 Maytag Services Installation Instructions Models AMC4080AA MMC5080AA ...
Page 49: ... 2004 Maytag Services 16023056 Rev 0 A 9 Installation Instructions ...
Page 53: ... 2004 Maytag Services 16023056 Rev 0 A 13 Installation Instructions ...
Page 56: ... 2004 Maytag Services 16023056 Rev 0 B 1 Appendix B ...