Filter Removal

Depending  on  the  installation,  differing  filter  arrangements 

can be applied. Filters can be installed in either the central 

return  register  or  a  side  panel  external  filter  rack  (upflow 

only). A media air filter or electronic air cleaner can be used 

as an alternate filter. Follow the filter sizes given in the Rec

-

ommended Minimum Filter size table or instruction provided 

by the media or electronic air cleaner manufacturer to ensure 

proper unit performance.

To remove filters from an external filter rack in an upright up

-

flow installation, follow the directions provided with external 

filter rack kit. 

Induced Draft and Circulator Blower Motors

The bearings in the induced draft blower and circulator blow-

er motors are permanently lubricated by the manufacturer. 

No further lubrication is required. Check motor windings for 

accumulation of dust which may cause overheating. Clean 

as necessary.

Flame Sensor (Qualified Servicer Only)

Under some conditions, the fuel or air supply can create a 

nearly  invisible  coating  on  the  flame  sensor.  This  coating 

acts as an insulator causing a drop in the flame sense sig

-

nal. If the flame sense signal drops too low the furnace will 

not sense flame and will lock out. The flame sensor should 

be carefully cleaned by a qualified servicer using steel wool.  

The flame sense signal should be 1 to 3 microamps.

Igniter (Qualified Servicer Only)

At room temperature, the igniter ohm reading should be from 

37 - 68 ohms.

Burners

WARNING

To prevent personal injury or death, do not remove any 

internal compartment covers or attempt any adjustment. 

Electrical components are contained in both compartments. 

Contact a qualified service agent at once if an abnormal 

flame appearance should develop.

Periodically during the heating season, make a visual check 

of the burner flames. Turn the furnace on at the thermostat.  

Wait a few minutes, since any dislodged dust will alter the 

normal flame appearance. Flames should be stable, quiet, 

soft and blue with slightly orange tips.  They should not be 

yellow.  They should extend directly outward from the burner 

ports without curling downward, floating or lifting off the ports.

Cleaning (Qualified Servicer Only)

1. 

Shut off electric power and gas supply to the furnace.

2. 

Disconnect the rollout limit wires, flame sensor wire, 

and disconnect the igniter plug.

CAUTION

Label all wires prior to disconnection when servicing 

controls. Wiring errors can cause improper and dangerous 

operation. Verify proper operation after servicing.

3.  Remove four (4) screws securing the burner box top.

CAUTION

The igniter is fragile and can be easily damage. Use extreme 

caution when removing the burner box top.

4.  Remove the screws securing the burners to the burner 

bracket. Remove the burners. 

5. 

Use bottle brush to clean burner insert and inside of 

burner.

6.  Replace burner (opposite of removal). Ensure burners 

are fully seated on burner bracket and are properly 

aligned. Replace burner box top. Reconnect wiring.

7.  Turn on electric power and gas supply to the furnace.
8.  Check furnace for proper operation. Refer to 

“Operational 

Checks” 

section  to verify burner flame characteristics.

BEFORE LEAVING AN INSTALLATION

•  Cycle the furnace with the thermostat at least three 

times. Verify cooling and fan only operation.

•  Review the Owner’s Manual with the homeowner and 

discuss proper furnace operation and maintenance.

•  Leave literature packet near furnace.

REPAIR AND REPLACEMENT PARTS

•  When ordering any of the listed functional parts, be 

sure to provide the furnace model, manufacturing, and 

serial numbers with the order.

•  Although only functional parts are shown in the parts 

list, all sheet metal parts, doors, etc. may be ordered 

by description.

•  Parts are available from your distributor.

Functional Parts List-

    Blower/Collector Box Gasket  Gas Valve 

 

     

    Natural Gas Orifice   

Primary Limit Switch

    Propane Gas Orifice   

Rollout Limit Switch

    Burner 

 

 

Auxiliary Limit Switch

    Hot Surface Igniter   

Heat Exchanger

    Flame Sensor 

 

Door Switch

    Gas Manifold  

 

Transformer

    Ignition Control 

 

Blower Wheel

    Blower Mounting Bracket 

Blower Housing

    Pressure Switch 

 

Blower Cutoff

    Pressure Switch Hose 

Blower Motor

    Induced Draft Blower  

Motor Mount Bracket

    Collector Box  

 

Capacitor

Summary of Contents for Amana CES80 Series

Page 1: ...ces However if there is a direct conflict between existing practices and the content of this manual the precautions listed here take precedence RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION NOTE Please...

Page 2: ...he Return Air Ductwork 18 SEQUENCE OF OPERATION INTEGRATED IGNITION CONTROL 18 Power Up 18 Heating Mode 18 Cooling Mode 19 Fan Only Mode 19 START UP PROCEDURE AND ADJUSTMENT 19 Furnace Operation 19 Fu...

Page 3: ...se conditions are listed in the PRODUCT APPLICATION section of this manual WARNING To prevent possible property damage personal injury or death due to electrical shock the furnace must be located to p...

Page 4: ...a limiting factor in locating the furnace Shipping Inspection All units are securely packed in shipping containers tested according to International Safe Transit Association specifica tions The carton...

Page 5: ...fied by a qualified person according to these installation instructions Copy of the inspection report issued by carrier s repre sentative at the time damage is reported to carrier The carrier is respo...

Page 6: ...All venting shall be in accordance with the National Fuel Gas Code ANSI Z223 1 or applicable local building and or air conditioning codes NOTE Furnaces with NOx screens meet the Califor nia NOx emiss...

Page 7: ...s deicing salts or chemicals carbon tetrachloride halogen type refrigerants cleaning solutions such as perchloroethylene printing inks paint removers varnishes hydrochloric acid cements and glues anti...

Page 8: ...d will depend on the application and the clearanc es necessary Suspended Furnace Existing Furnace Removal NOTE When an existing furnace is removed from a venting system serving other appliances the ve...

Page 9: ...inspection R gler le thermostat de mani re ce que l appareil fonctionne en continu 7 V rifier la pr sence de fuite au niveau de l ouverture du coupe tirage des appareils qui en sont dot s apr s 5 minu...

Page 10: ...y NOTE The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system WARNING To prevent possible personal injury or death due to asphyxi...

Page 11: ...ensation damage is best avoided by using masonry chimney as a pathway for properly sized metal liner or Type B metal vent 7 Remove the chimney transition bottom from the transi tion bottom kit 8 Insta...

Page 12: ...nfigured for a right side electrical connection To make electrical connec tions through the opposite side of the furnace the junction box must be relocated to the left side prior to making elec trical...

Page 13: ...RNING To prevent personal injury or death due to electric shock disconnect electrical power before installing or servicing this unit 1 Remove both doors from the furnace 2 Remove and save the screws h...

Page 14: ...s used to share the call for fan operation between furnaces The duration of the pulse width determines the speed that the reading control will energize its blower motor CAUTION To prevent unreliable o...

Page 15: ...R10 9 R20 9 R100 R 96 R14 3 R20 7 R213 R215 CR1 R1 96 1 C R 1 0 R57 R7 R35 1 R48 R9 4 R6 2 R2 9 R98 R173 R12 2 R139 CR27 CR4 R19 5 R82R1 7 C1 9 C21 R158 C2 3 C1 4 C3 7 C38 R50 C3 6 R164 R172 C31 CR9 3...

Page 16: ...e resistant to the action of the fuel used Use ground joint unions Install a drip leg to trap dirt and moisture before it can enter the gas valve The drip leg must be a minimum of three inches long In...

Page 17: ...confined space it is strongly recommended to contact a propane supplier to install a gas detecting warning device in case of a gas leak Since propane gas is heavier than air any leaking gas can settle...

Page 18: ...the furnace casing and terminating outside the space containing the furnace Filters Read This Section Before Installing The Return Air Ductwork Filters must be used with this furnace Filters do not s...

Page 19: ...d control module mon itors safety circuits continuously R and G thermostat contacts open completing the call for fan Circulator blower is de energized Electronic air clean er terminals are de energize...

Page 20: ...repair leaks immediately 13 Turn ON electrical power and gas supply to the system 14 Turn valve switch ON position 8 Replace the door on the front of the furnace 9 Open the manual gas valve external...

Page 21: ...ivide the number of seconds recorded in step 2 by two 4 Calculate the furnace input in BTUs per hour BTU hr Input equals the installation s gas heating value multiplied by a conversion factor hours to...

Page 22: ...an the input indi cated on the unit rating plate 5 Turn ON gas and relight appliances turned off in step 1 Ensure all the appliances are functioning properly and that all pilot burners are operating T...

Page 23: ...external static pressure exceeds the maximum listed on the furnace rating plate check for closed dampers registers undersized and or oversized poorly laid out duct work Digital Manometer Checking Stat...

Page 24: ...10 K8 K6 K7 1 U1 DS1 OFF O N SW1 OFF ON SW2 1 2 3 4 SW3 CR25 CR29 CR30 CR32 CR17 CR1 1 CR1 0 CR1 2 CR4 0 CR15 CR13 CR7 CR3 CR35 CR19 CR18 CR26 CR34 CR2 1 CR33 Q10 Q12 Q14 Q6 CR4 CR1 CR6 CR9 CR14 CR16...

Page 25: ...re Switches The pressure switches are normally open negative air pres sure activated switches They monitor the airflow combus tion air and flue products through the heat exchanger via pressure taps lo...

Page 26: ...isconnect electrical power to the furnace BEFORE removing the filter or performing any other maintenance TROUBLESHOOTING Diagnostic Chart Refer to the troubleshooting chart in the Appendix for assis t...

Page 27: ...htly orange tips They should not be yellow They should extend directly outward from the burner ports without curling downward floating or lifting off the ports Cleaning Qualified Servicer Only 1 Shut...

Page 28: ...er Door Interlock Switch 15 Circulator Blower 16 Gas Line Entrance Alternate COMPONENT ID Pressure Switch Tubular Heat Exchanger Flue Pipe Connection Gas Line Entrance Alternate Induced Draft Blower C...

Page 29: ...ed gas supply lazy burner flames improper gas pressure or restriction in flue and or improper induced draft blower performance Locate and correct gas interruption Replace or realign igniter Check flam...

Page 30: ...heck burners for proper alignment Check flue for blockage proper length elbows and termination Correct as necessary Check rollout limit Replace if necessary Check induced draft blower for proper perfo...

Page 31: ...rrect unit ground wire Replace bad integrated control module Turn power OFF prior to repair Replace igniter w proper replacement part Read precautions in Electrostatic Discharge Furnace not operating...

Page 32: ...N A 1410 1400 1358 OFF ON 1820 N A 1769 N A 1726 N A 1685 N A 1642 N A 1603 1557 1521 DIP SWITCHES S2 1 S2 2 EXTERNAL STATIC PRESSURE INCHES WATER COLUMN 0 1 0 2 0 3 0 4 0 5 801005C 800403A 800603A 80...

Page 33: ...82 229 197 ON ON ON 784 716 645 583 516 405 334 282 229 197 ON OFF OFF 1295 1252 1203 1153 1114 1071 1022 981 931 883 ON ON OFF 1401 1366 1320 1278 1236 1194 1153 1112 1070 1025 OFF ON OFF 1596 1553 1...

Page 34: ...11 59 965 61 920 868 818 OFF OFF 743 N A 668 N A 599 N A 522 N A 432 N A 366 312 258 ON OFF 1408 42 1369 43 1319 45 1282 46 1242 48 1219 1193 1150 ON ON 1179 50 1123 53 1073 55 1025 58 972 61 949 924...

Page 35: ...ON 1402 1358 1317 1274 1234 1195 1154 1113 1069 1033 OFF OFF 743 668 599 522 432 366 312 258 213 158 ON OFF 1408 1369 1319 1282 1242 1193 1150 1109 1069 1025 OFF ON 1574 1521 1481 1439 1398 1374 1335...

Page 36: ...335 263 232 195 ON ON ON 752 678 608 547 474 403 335 263 232 195 ON OFF OFF 1330 1280 1229 1187 1146 1103 1061 1018 977 936 ON ON OFF 1155 1100 1048 1002 952 907 861 816 789 741 OFF ON OFF 1418 1376...

Page 37: ...652 466 499 428 346 294 246 202 OFF ON ON 822 754 652 466 499 428 346 294 246 202 ON OFF ON 822 754 652 466 499 428 346 294 246 202 ON ON ON 822 754 652 466 499 428 346 294 246 202 ON OFF OFF 1352 12...

Page 38: ...agram on the unit for the most up to date wiring MES80 CES80 WIRING DIAGRAM HIGH VOLTAGE D ISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT M ULTIPLE POWER SOURCES MAY BE PRESENT F AILURE...

Page 39: ...se DB F Delta T Difference between Supply and Return Temperatures DB F GAS PRESSURES Gas Inlet Pressure IN W C Gas Manifold Pressure Low Fire IN W C Gas Manifold Pressure High Fire IN W C Gas Type NG...

Page 40: ...register their product does not diminsh their warranty rights For Product Registration please register by following this link Goodman Brand Products https www goodmanmfg com product registration Amana...

Reviews: