A – 6
16023515
©2005 Maytag Services
Installation Instructions
(Model ALZ8590AD*)
1.
CAUTION:
LIQUIFIED PETROLEUM (L.P.)/PRO-
PANE GAS SUPPLY LINE MUST HAVE A L.P. GAS
PRESSURE REGULATOR. INLET PRESSURE TO
THIS APPLIANCE SHOULD BE REDUCED TO A
MAXIMUM OF 14 INCHES WATER COLUMN (0.5
P.S.I.) INLET PRESSURES IN EXCESS OF 0.5 P.S.I.
CAN DAMAGE THE APPLIANCE PRESSURE
REGULATOR AND OTHER GAS COMPONENTS IN
THIS APPLIANCE AND CAN RESULT IN A GAS
LEAK.
2. Cut opening in accordance with figure 1 shown below.
Installation For RV Cooktops
Figure 1
Figure 2
20
15
3
3 MIN. TO
REAR WALL
3 MIN. TO SIDE WALLS
20
15
FOAM
GASKET
MOUNTING BRACKET
MOUNTING SCREW
3. Place the cooktop upside down on a protected surface
and place the 1/2 x 1/2 foam strip on the underside of
the glass around the perimeter of cooktop to seal
between cooktop and counter. (See figure 2).
4. Place the cooktop in position and fasten down with
screws and mounting brackets. (See figure 2).
Art #: 9215-188
Figure 3
FLEXIBLE CONNECTOR
SHUTOFF
VALVE
BLACK TO (-) NEGATIVE
RED TO (+) POSITIVE
FLEXIBLE CONDUIT
POWER SOURCE: 9 TO 12 VDC
PRIOR TO STEPS 5 & 6, MAKE SURE BOTH KNOBS
ARE IN THE “OFF
” POSITION.
5. Connect ignition wires to 12 VOLT DC power source,
as shown in figure 3. (Black to negative and Red to
positive).
6. Connect gas supply line to .625-18UNF-2A nipple at
back of unit. (See figure 3).
NOTE:
If local codes and ordinances permit, A.G.A.
design certified, new flexible metal tubing is recom-
mended for connecting cooktop to the gas supply line.
7. Check all gas connections for leaks with non corrosive
leak detection fluid.
Do not use open flames for
checking gas leaks.