©2005 Maytag Services
16023515
C – 3
LP Conversion Instructions
(Models CG11000AD*, CPL1110AD*,
YPL1110AD*)
Top Burner Conversion
1. Remove four (4) burners from valve orifice hoods.
NOTE:
Remove burner shipping screws if installed.
Removing Orifice Hoods
2. Remove four (4) orifice hoods from burner valves.
3. Apply sealant.
4. Attach four (4) orifice hoods to valve (see table).
5. Adjust top burner air shutters. For Natural Gas, open air shutter approximately ¼ (one-fourth) of total air
shutter opening. For LP, fully open air shutter.
6. Reattach four (4) burners to valve orifice hoods.
Oven Burner Conversion
1.
Remove broiler pan, lift broiler safety stop and remove broiler drawer.
2.
Remove oven rack(s). Loosen, but do not remove, screws securing bottom oven panel. Remove bottom
oven panel.
3.
Remove burner bar screws. Lift and remove oven burner and lay to one side.
4.
Remove oven orifice from oven valve/safety valve.
5.
Apply sealant and attach oven orifice (see table).
6.
Adjust oven burner air shutter. For Natural Gas, open air shutter approximately ¼ (one-fourth) of total air
shutter opening. For LP, fully open air shutter.
7.
Attach oven burner to oven valve/safety valve, and attach burner bar screws.
8.
Replace oven bottom panel, tighten screws, and replace oven rack(s).
9.
Replace broiler drawer (lift safety pin and install). Replace broiler pan.
10. Apply sealant to gas supply connector and attach gas supply line to pressure regulator.
11. Turn on gas supply and check for leaks. Return range to installation position and proceed to “Lighting Pilot”
procedure.