281114 v1.3
Operating Instructions USi
Page 35/43
Polymer Electric
Conformity
Factory Settings
The USi is returned to the condition supplied to the customer by performing RESET.
The factory settings stored in the USi thereby overwrite all current parameters.
The standard values apply respectively for Sensor
1
and
Sensor
2.
Display tab
Parameter
Standard value
Standard
Operating mode
1 range
Switch point SP1
1 [cm]
Switch point SP2
200 [cm]
OUT 1.1 (output 1.1) *
Normally open contact/
analog
OUT 1.2 (output 1.2) *
Normally open contact
OUT 2.1 (output 2.1) *
Normally open contact
OUT 2.2 (output 2.2) *
Normally open contact
Switching behaviour*
Switch
Measurement resolution *
cm
Device synchronisation *
Off
Expert mode
Echo gain *
5 [–]
Sensitivity *
5 [–]
Multiple scan *
3 [–]
Power-on delay *
10 [–]
Close range to *
16 [cm]
Echo distribution from *
50 [cm]
Hysteresis *
0 [cm]
Object size *
Medium
Object detection *
Automatic
Transducer mode *
Transmitter and receiver
Transmitting intensity*
max.
Transducer priority *
Off
Interference suppression *
High / 1 s
Measurement frequency *
Measurement delay min. *
Measurement delay max.*
Middle (ca. 20 Hz)
9 [ms]
13 [ms]
Temperature compensation *
Co18 °C
Diagnosis
TVG *
TVG standard
Select oscillogram *
Echo digital
Distance display *
cm
* Parameter can only be changed with parameter
assignment software
Conformity
The design type of the product complies with the basic requirements of the follow-
ing directives:
r
2004/108/EC (EMC)
The Declaration of Conformity is available in the Downloads section of our website:
www.mayser-sicherheitstechnik.de