Commissioning
LEDs
Meaning
Power
Operation
green
OUT 1.1
Output 1.1
yellow
OUT 1.2
Output 1.2
yellow
OUT 2.1
Output 2.1
yellow
OUT 2.2
Output 2.2
yellow
LED off:
LED on:
Display of the speci
fi
c error: Sensor
1 missing;
the yellow LEDs go off after 1
s
Display of the speci
fi
c error: Sensor
2 missing;
the yellow LEDs go off after 1
s
Display of the speci
fi
c error: no sensor connect-
ed; the yellow LEDs go off after 1
s
2. Place an object in the detection
fi
eld of sensor
1. Make sure that the detection
fi
eld of sensor
2 remains clear.
-
Green LED “Power” is lit
-
Yellow LEDs “OUT 1” and “OUT 1.2” are lit
-
USi-PP: Outputs 1.1 and 1.2 are closed
USi-IP/UP: analog Signal at output 1.1, output 1.2 is closed
-
Yellow LEDs “OUT 2” and “OUT 2.2” are off
-
Outputs 2.1 and 2.2 are open
1. Make sure that the detection
fi
elds from sensor
1 and sensor
2 are clear.
-
Green LED “Power” is lit
-
All yellow LEDs are off
-
All outputs are open
Testing the Function
4. Place an object in the detection
fi
eld of Sensor
2. Make sure that the detection
fi
eld of Sensor
1 remains clear.
-
Green LED “Power” is lit
-
Yellow LEDs “OSSD 1.1” and “OSSD 1.2” are off
-
Outputs 1.1 and 1.2 are open
-
Yellow LEDs “OSSD 2.1” and “OSSD 2.2” are lit
-
Outputs 2.1 and 2.2 are closed
3. Repeat Step 1.
All tests passed? – If so, your USi is now ready for operation.
The following description applies for USi with two sensors.
For USi with only one sensor, the functional test is completed after Step 2.
TIP: Diagnosis
. Lack of earthing may cause malfunctions. With the
Continuous
echo diagnostics
in the parameter assignment software (optional), you can
quickly detect a lack of earthing.