Page 18/43
Operating Instructions USi
281114 v1.3
Polymer Electric
Installation
3. Lay the cable of the sensor at sufficient distance to sources of electromagnetic
interference, like e.g. direct current motors.
Malfunction due to incorrect mounting
Squeezing the sensor – particularly in the front area near the active surface – can
cause malfunctions and mechanical damage.
Ä
Only attach the sensor with the recommended O-rings.
Ä
Do not use the cable as a pulling aid. The cable can tear off.
Ä
Avoid high mechanical loads on the active surface (heavy pressure, impact,
etc.) when mounting.
Ä
Immediately replace damaged sensor (torn off cable, damaged active
surface). Repairs are not possible.
Alternative: Enclosure set (optional)
Instead of using your own brackets you can also use one of the Mayser enclosure
sets. See Chapter
Accessories
for a small selection. The installation steps are the
same as described above.
Mounting the Evaluation Unit
The Evaluation Unit can be mounted in any position. If the Evaluation Unit is to be
mounted in a splash water environment, the parameter assignment situation via
USB connection must be considered. If the screw plug is removed, the protection
class drops to IP20. The opening for the USB connection should therefore be con-
fi
gured in such a way that it preferably faces down and not in the direction of the
source of the splash water. We recommend the installation of an additional splash
water protection during parameter assignment (guard plate, foil, or similar).
Ä
Fix the Evaluation Unit in any position with two screws Ø
3
mm.
CAUTION