Safety Regulations 

These Safety Regulations are user hints only and must not be complete! 

 

 
Danger! 
Danger of death! Do not touch voltage-carrying 
cables and components. 
 

To prevent injury or damage, only professionals and 
specialists should work on the devices. 
 
Danger! 
 
This warning applies if: 

 

the electromagnetic clutch is used incorrectly. 

 

the electromagnetic clutch is modified. 

 

the relevant standards for safety and / or installation 
conditions are ignored. 

 
 

Warning! 
Before product installation and initial operation, 
please read the Installation and Operational 
Instructions carefully and observe the Safety 
Regulations. Incorrect operation can cause injury or 
damage. 
The electromagnetic clutches have been developed 
in accordance with the latest technology regulations 
and are, at the point of delivery, operationally safe. 

 
Warning: 
Without a conformity inspection, this product is not suitable for 
use in areas where there is a high danger of explosion. This 
statement is based on the directive 94/9/EC (ATEX directive). 
 
Please Observe! 

 

Only specialists who are trained in the transport, 
installation, operation, maintenance and general operation 
of these devices and who are aware of the relevant 
standards should be allowed to carry out this work.  

 

Technical data and specifications (Type tags and 
documentation) must be followed.  

 

The correct connection voltage must be connected 
according to the Type tag. 

 

Never loosen electrical connections or carry out 
installations, maintenance or repairs while the voltage 
connection is energised! 

 

Cable connections must not be placed under mechanical 
strain. 

 

Check electrical components for signs of damage before 
putting them into operation. Never bring them into contact 
with water or other fluids. 

 

The torque is lost if the friction lining and / or the friction 
surface come into contact with oil or grease. 

 

Appointed Use  

ROBATIC

 ®

-clutches are for use in machines and systems and 

must only be used in the situations for which they are ordered 
and confirmed. 
Using them for any other purpose is not allowed! 

Guidelines for Electromagnetic Compatibility 
(EMC)

 

In accordance with the EMC directives 89/336/EEC, 
the individual components produce no emissions. 
However, functional components e.g. rectifiers, 
phase demodulators, ROBA

®

-switch devices or 

similar controls for mains-side energisation of the 
clutches can produce disturbance which lies above 
the allowed limit values.  
For this reason it is important to read the Installation 
and Operational Instructions very carefully and to 
keep to the EMC directives. 

 

 

Device Conditions 

The catalogue values are standards which can, in 
certain cases, vary. When dimensioning the 
clutches, please remember that installation 
situations, torque fluctuations, permitted friction 
work, run-in behaviour and wear as well as general 
ambient conditions can all affect the given values. 
These factors should therefore be carefully 
assessed, and alignments made accordingly. 
 

Please Observe!  

 

Mounting dimensions and connecting dimensions must be 
adjusted according to the size of the clutch at the place of 
installation.  

 

The clutches are designed for a relative duty cycle of  
100 %.  

 

The clutches are only designed for dry running.  
The torque is lost if the friction surfaces come into contact 
with oil, grease, water or similar substances. 

 

The torque is dependent on the present run-in condition of 
the clutches. 

 

Manufacturer-side corrosion protection of the metallic 
surface is provided. 

 

Protection Class I 

This protection can only be guaranteed if the basic insulation is 
intact and if all conductive parts are connected to the PE 
conductor of the permanent installation. Should the basic 
insulation fail, the contact voltage cannot remain (VDE 0580). 
 

Protection (Electrical) IP 54: 

Dust-proof and protected against contact as well as against 
splashing water from all directions. 
Valid for coil, casting compound and connection strands. 
On the design with a connection terminal, the connection 
terminal itself corresponds to Protection Class IP00.
 
 

Ambient Temperature –20 °C up to +40 °C 

Warning! 

At temperatures of around or under freezing point, condensation 
can strongly reduce the torque. During longer downtimes, the 
friction surfaces can stick. The user is responsible for taking 
appropriate counter measures. 
 

Thermic Class F (+155 °C) 

The magnetic coil and the casting compound are suitable for use 
up to a maximum operating temperature of +155 °C.  
 

Summary of Contents for ROBATIC 500.1 Series

Page 1: ...eristics Run in Conditions Page 6 Installation Examples Boring the Rotor Hub Page 7 Installation Rotor De installation Rotor Turn on for the Ball Bearing Electrical Connection Page 8 Maintenance and I...

Page 2: ...which they are ordered and confirmed Using them for any other purpose is not allowed Guidelines for Electromagnetic Compatibility EMC In accordance with the EMC directives 89 336 EEC the individual co...

Page 3: ...lity Install additional protective measures against corrosion if the brake is subject to extreme ambient conditions or is installed in open air conditions unprotected from the weather Take precautions...

Page 4: ...7 8 9 Nominal torque M2 1 Nm 10 20 45 80 160 320 640 Maximum bore dmax in rotor 3 mm 20 25 30 40 55 70 80 Air gap a Figs 3 4 mm 0 2 1 0 05 0 0 2 15 0 05 0 0 2 15 0 05 0 0 3 15 0 05 0 0 3 15 0 05 0 0...

Page 5: ...which the closed clutch can be loaded without slipping occurring The relative duty cycle is the ratio of duty cycle to backlash duration in percent duty cycle Table 2 Size Friction work Qa J Clutch sp...

Page 6: ...tion Example 2 Fig 4 Electromagnetic clutch with flange hub 7 for the connection of two aligning shafts Torque Procedure Input shaft rotor 3 armature disk 4 flange hub 7 output shaft The coil carrier...

Page 7: ...he flange hub 7 observe the tightening torque acc Table 1 3 3 Align the armature disk 4 max permitted radial run out 0 15 mm Please Observe The armature disk 4 must be kept grease free 4 Installation...

Page 8: ...e observe the relevant authority regulations Code numbers must vary according to the dismantling process metal plastic and cable Electronic components Rectifier ROBA switch Products which have not bee...

Reviews: