34
25
4,5
Ø3,5
19
5
30
Application
Reduces spark production on the switching contacts occurring
during VDC inductive load switching.
• Voltage limitation according to VDE0580 2000-07, Item 4.6.
• Reduction of EMC-disturbance by voltage rise limitation,
suppression of switching sparks.
• Reduction of brake engagement times by a factor of 2-4
compared to free-wheeling diodes.
Function
The spark quenching unit will absorb voltage peaks resulting from
inductive load switching, which can cause damage to insulation
and contacts. It limits these to 70V and reduces the contact load.
Switching products with a contact opening distance of > 3 mm are
suitable for this purpose.
Electrical Connection
(Terminals)
1 (+) Input voltage
2 (–) Input voltage
3 (–) Coil
4 (+) Coil
5 Free nc terminal
6 Free nc terminal
Technical Data
Input voltage
max. 300 VDC, max. 615 V
peak
(rectified voltage 400 VAC,
50/60 Hz)
Switch-off energy
max. 9J/2 ms
Power dissipation
max. 0,1 Watt
Max. voltage nc terminals
250 V
Protection
IP65 / IP20 terminals
Ambient temperature
-25 °C up to +85 °C
Storage temperature
-25 °C up to +105 °C
Max. conductor connection
diameter
2,5 mm
2
/ AWG 26-12
Max. terminal tightening torque 0,5 Nm
Accessories
Mounting bracket set for 35 mm rail acc. to EN50022
Article-No. 1803201
Dimensions
(mm)
Order Number
__ / 0
7
0 . 0
0
0 . 6
Size
1
Spark Quenching Unit Type 070.000.6
18
18