background image

Supply module

Protective 

Circuit

no overexcitation

and 

no power reduction

overexcitation (short separation time) 

and / or

 power reduction (reduction in coil capacity and temperature)

variable  

output 

voltage

fixed

  

output 

voltage

without

  

DC-side  

disconnection

integrated  

DC-side  

disconnection

Type  

04.000.6

Type  

05.000.6

Type  

017._00.

Type  

017.110.

Type  

018.100.

Type  

019.100.

Type  

070.000.6

Half-wave 

Rectifier

Bridge  

Rectifier

ROBA

®

-switch

ROBA

®

-switch

ROBA

®

-switch 

4V

ROBA

®

multiswitch

Spark  

Quenching Unit

APPLICATION

Standard  

application 

Standard  

application, 

preferred for 

noise-damped 

brakes 

Allows short separation time

 or reduction in coil capacity and temperature

Reductions  

in switch-off 

voltage and 

wear on  

contacts

+

short

connection time

+

short

connection time 

(for 

input 

voltage 

24 VDC) 

+

consistently  

controlled 

output 

voltage  

with variable

input 

voltage 

compact

design

compact 

design

no wear on 

contacts

no wear on 

contacts

over

207 VDC (Overexcitation voltage)

over

360 VDC (Overexcitation voltage)

Type  

017._00.

Type  

017._00.

ROBA

®

-switch

ROBA

®

-switch

nom

104 VDC (Coil nominal voltage)

nom

207 VDC (Coil nominal voltage)

hold

180 VDC (Holding voltage)

0

0

t

t

Example 1

Available:  

network voltage 230 VAC

Wanted:  

short separation time (overexcitation)

Required:  

supply module / coil nominal voltage

Solution: 

Supply modules available for selection: Type 017._00.2 
(in Example below), Type 017.110.2 or Type 019.100.2
Coil nominal voltage: 104 VDC

Example 2

Available:  

network voltage 400 VAC

Wanted:  

short separation time (overexcitation) and  

  

and low coil temperature (power reduction)

Required:  

supply module / coil nominal voltage

Solution: 

Supply modules available for selection: Type 017._00.2 (in 
Example below), Type 017.110.2 or Type 019.100.2
Coil nominal voltage: 207 VDC

Overview/Assortment Electrical Accessories

13

13

Summary of Contents for ROBA-stop-M

Page 1: ...OBA stop M Electromagnetic safety brakes Fast and cost effective installation High Protection IP54 IP65 Maintenance free for the rotor lifetime your reliable partner ROBA stop Always the safest choice...

Page 2: ...d condition helical springs 6 press against the armature disk 5 The rotor 3 is held between the armature disk 5 and the corresponding mounting surface of the machine The shaft is braked via the gear h...

Page 3: ...s in this document are represented with a comma e g 0 5 instead of 0 5 We reserve the right to make dimensional and constructional alterations 1 Hand release not installed on sizes 2 500 Size 1000 han...

Page 4: ...250 500 1 2 1000 5 Holding brake 1 2 Type 891 1_ _ _ Mnom Nm 4 8 16 32 64 100 180 250 450 800 3 1600 5 Input power Pnom W 19 25 29 38 46 69 88 98 120 152 186 Maximum speed nmax rpm 6000 5000 4000 350...

Page 5: ...IN IEC 60038 10 Outer diameter friction disk free size outer diameter flange plate 0 2 Missing dimensions are identical with Type 891 011 0 see page 4 Dimensions mm Size 2 4 8 16 32 60 100 150 250 500...

Page 6: ...nal condition by replacing the rotor For this the brake must be cleaned thoroughly The wear condition of the rotor 3 is determined by measuring the release voltage this must not exceed max 90 of the n...

Page 7: ...mm 6 05 6 05 6 9 8 10 4 11 15 14 15 5 17 18 5 18 5 Table 1 Permitted Bores dmax Size 2 4 8 16 32 60 100 150 250 500 1000 dmax Type 891 0_ _ _ 2 Keyway JS9 6885 1 13 13 18 22 30 32 42 45 55 75 90 6885...

Page 8: ...tching frequency can be taken from the friction power diagrams page 9 If the friction work switching work per braking is known the max switching frequency can also be taken from the friction power dia...

Page 9: ...250 Size 150 Size 100 Size 60 Size 32 Size 16 Size 8 Size 4 Size 2 Switching frequency 1 h Diagram 2 Type 891 10_ _ Holding brake Type 891 10_ _ Holding brake for 50 of the maximum speed nmax for the...

Page 10: ...1 page 5 as part of the standard delivery A radial shaft sealing ring Item 1 is installed in the coil carrier Item 2 on continuous shafts Damping rotor gear hub If vibrations in the drive line cannot...

Page 11: ...observe the applicable directives and standards e g DIN EN 60204 1 and DIN VDE 0580 Their observance must be guaranteed and double checked Earthing Connection The brake is designed for Protection Cla...

Page 12: ...g force braking torque adjustment 100 The overexcitation time tover is double the separation time t2 on each brake size Spring force braking torque adjustment 100 The overexcitation time tover is high...

Page 13: ...controlled output voltage with variable input voltage compact design compact design no wear on contacts no wear on contacts U over 207 VDC Overexcitation voltage U over 360 VDC Overexcitation voltage...

Page 14: ...7 W 517 W 312 W 416 W 416 W 416 W Max coil capacity at 230 VAC up to 85 C 352 W 352 W 187 W 250 W 250 W 250 W Max coil capacity at 400 VAC 50 C 540 W 720 W 720 W 720 W Max coil capacity at 400 VAC up...

Page 15: ...n Terminals 1 2 Input voltage fitted protective varistor 3 4 Connection for external contact for DC side switch off 5 6 Output voltage fitted protective varistor 7 8 Rext for bridge rectifier timing a...

Page 16: ...tive measures or external components are necessary The DC side disconnection is stand ard activated terminals 3 and 4 are not wired resulting in short electromagnetic consumer switching times The inte...

Page 17: ...bridge voltage for 50 ms and then control the 90 or 180 VDC overexcitation voltages After the overexcitation period they control the 52 or 104 VDC holding voltages The overexcitation period can be adj...

Page 18: ...load Switching products with a contact opening distance of 3 mm are suitable for this purpose Electrical Connection Terminals 1 Input voltage 2 Input voltage 3 Coil 4 Coil 5 Free nc terminal 6 Free nc...

Page 19: ...must be adjusted according to the size of the brake at the place of installation The brakes are designed for a relative duty cycle of 100 The brakes are only designed for dry running The braking torqu...

Page 20: ...7 contact mayr fr Italy Mayr Italia S r l Viale Veneto 3 35020 Saonara PD Tel 0 49 8 79 10 20 Fax 0 49 8 79 10 22 info mayr italia it Singapore Mayr Transmission S PTE Ltd No 8 Boon Lay Way Unit 03 06...

Reviews: