Supply module
Protective
Circuit
no overexcitation
and
no power reduction
overexcitation (short separation time)
and / or
power reduction (reduction in coil capacity and temperature)
variable
output
voltage
fixed
output
voltage
without
DC-side
disconnection
integrated
DC-side
disconnection
Type
04.000.6
Type
05.000.6
Type
017._00.
Type
017.110.
Type
018.100.
Type
019.100.
Type
070.000.6
Half-wave
Rectifier
Bridge
Rectifier
ROBA
®
-switch
ROBA
®
-switch
ROBA
®
-switch
4V
ROBA
®
-
multiswitch
Spark
Quenching Unit
APPLICATION
Standard
application
Standard
application,
preferred for
noise-damped
brakes
Allows short separation time
or reduction in coil capacity and temperature
Reductions
in switch-off
voltage and
wear on
contacts
+
short
connection time
+
short
connection time
(for
input
voltage
24 VDC)
+
consistently
controlled
output
voltage
with variable
input
voltage
compact
design
compact
design
no wear on
contacts
no wear on
contacts
U
over
207 VDC (Overexcitation voltage)
U
over
360 VDC (Overexcitation voltage)
Type
017._00.
Type
017._00.
ROBA
®
-switch
ROBA
®
-switch
U
nom
104 VDC (Coil nominal voltage)
U
nom
207 VDC (Coil nominal voltage)
U
hold
180 VDC (Holding voltage)
0
0
t
t
Example 1
Available:
network voltage 230 VAC
Wanted:
short separation time (overexcitation)
Required:
supply module / coil nominal voltage
Solution:
Supply modules available for selection: Type 017._00.2
(in Example below), Type 017.110.2 or Type 019.100.2
Coil nominal voltage: 104 VDC
•
•
Example 2
Available:
network voltage 400 VAC
Wanted:
short separation time (overexcitation) and
and low coil temperature (power reduction)
Required:
supply module / coil nominal voltage
Solution:
Supply modules available for selection: Type 017._00.2 (in
Example below), Type 017.110.2 or Type 019.100.2
Coil nominal voltage: 207 VDC
•
•
Overview/Assortment Electrical Accessories
13
13