2202G1JE-DA-M-N_2010.01.
1 Safety
Reciprocating Compressor M Series
1.4 Safety Devices
1-14
1.4.6 Compressor Cooling Fluid Temperature Failure Alarm
Overview/Function/Purpose
Prevents the head cover and refrigerant oil from becoming too hot by stopping the compressor.
Installation
Positions
Cooling Fluid system
Settings
Specify the settings of cooling fluid temperature failure alarm, and make sure to provide users of this
compressor with them.
Inspection
Method/Cycle
The Cooling Fluid failure alarm requires operational test before operating the compressor and periodically
testing after that. Specify the inspection methods/cycle of cooling fluid temperature failure alarm, and make
sure to provide users of this compressor with them.
1.4.7 Oil Heater and Thermometer Switch
Always insure the Oil heater and thermometer switch are completely immersed in
oil before applying power. If power is applied to heater damage to the heater will
occur, destroying the element from dry burn. Pay constant attention to the oil
level while applying power to the heater.
Overview/Function/Purpose
The oil heater is a cartridge type covered heater. It is pressure-proof sealed type with heating wires wrapped
with insulator and externally sealed with stainless tube.
The oil heater is used to prevent refrigerant from dissolving in oil or condensing in the crank case during the
off cycle of the compressor.
Installation
Positions
The thermometer switch which controls temperature of heater is attached inside the heater.
Settings
Specify the thermometer switch settings, and make sure to provide users of this compressor with them.
Inspection
Method/Cycle
The thermometer switch requires set up and testing before operating the compressor and periodically after that.
Specify the inspection methods/cycle of the thermometer switch, and make sure to provide users of this
compressor with them.