Before connecting gas pipes, please check:
Whether the type of gas supplied matches that
specified on the name plate of boiler. Any other
types of gas not specified on the name plate shall
not be used.
Whether the gas pipes are clean.
Please install a gas filter if there are solid
particles in gas. Please check the tightness of all
connections after installation.
Do not use the gas pipe as the earth wire.
There must be a pipe, which connects outlet of
safety valve to the ground.
Please use the supplied flue gas pipe.Do not
modify the flue gas pipe.
The flue gas pipe shall be installed with a 2-degree
slope outward to ensure the condensation water
flows out.
The flue gas pipe must be wrapped with refractory
material thicker than 200mm when it goes through
a wall with combustive materials. Do not lay the
pipe into ceiling.If you have to do this,cover the
flue gas pipe with refractory material thicker than
20mm.
The space between the flue gas pipe and the wall
it goes through shall not be filled with hard articles
such as cement.which makes it inconvenient for
maintenance.
The outlet and inlet of flue gas pipe shall be
extended to the outside wall,and shall not be
blocked.Keep the ventilation of exhaust and air-
entering.
The distance between the upper edge of the flue
gas pipe and the above building shall be more
than 45mm.
If extended pipe are used,all the joints must be
well sealed and there shall be no leakage of flue
gas into house.
The coaxial flue gas may be adjusted to the most
suitable direction according the requirement of
installation. The chart below show the linear lenghts
of flue gas pipe with and without flow-limiting ring.
The flow limiting ring shall be removed with a screw
driver.
Drill a hole of 105mm on the wall according to
the installation module.The whole shall have a
downward of 2 degree toward outside.
If the flue gas pipe is installed in the side
wall,draw a horizontal line from the centre of the
module to the centre of the outlet flue gas pipe.
Draw a circle of 105mm centering the centre of
the outlet of the flue gas pipe.
Drill according to the circle drawn above.
MGBWA100N11LA
Summary of Contents for Volcan MGBWA0100
Page 1: ...MGBWA070 MGBWA090 MGBWA0100 Volcan Series...
Page 12: ......
Page 13: ......
Page 15: ......
Page 17: ...MGBWA100N11LA...
Page 22: ......