background image

The  circulation  pump  head  and flow should 

match the boiler system

The  whole  system  should   be  clean,with   no 

sediment, rust, leakage, and drip-drop. 

While   affusing   and   refilling   water. a water-

purification must be equipped.

Don't install the boiler to the place close to any 

combustible material.
The wall on which the boiler is installed must be 

able to support a hang weight of 45KG,and if it's 

made of combustive materials,it should be 

covered with anti-combustive at least 3 mm thick. 

Never install the boiler in places where 

combustion and volatile drugs are stored or used. 

Don't install the boiler under any dangerous shelf 

staff that maybe drop.

Don't   install   the    boiler   above   other   gas

applications.

The outlet of the flue gas pipe shall be installed at

places with good ventilation.

For natural gas and LPG users, D15 gas pipe can

be  used.   However we  advise  you  use  D20

pipe,the reducer pipe connecting with the gas

meter should less than D15.

Keep a stable voltage of 110V,Use constant

voltage regulator.

It is forbidden to use hemp thread for connecting

pipe. Use coarse plastic tapes. If hemp thread has

to    be    used    in    certain    conditions,please

completely clean the pipes with compressed air

at 8 bar pressure.

Radiator of 150 square meter might be installed

in your room—you have to install the Y-shape

filter in the return water of heating system.

The outlet of safety valve must be connected to

floor drainage, there shall not be any valve on

connection pipe.

For   system   with   cast   iron   radiators,please

completely clean the pipes and radiators with

high-pressure water or compressed air at 8 bar

pressure.In    areas   where   water   quality   is

poor,please clean the system several times. Use

softened water for affusion of system.

Summary of Contents for Volcan MGBWA0100

Page 1: ...MGBWA070 MGBWA090 MGBWA0100 Volcan Series...

Page 2: ...e must be airproofing only gas pipe installation qualified company can do it 2 If there is any defect in the installation of exhausted air discharging system it will be possible for the exhaust regorg...

Page 3: ...n 07 water filling 08 Affusion and Drainage 08 Circuit digram of boiler 10 User manual 11 13 Malfunction display and solutions 14 For Installation and maintenance 15 22 Unpacking Inspection and Accept...

Page 4: ...cally to release pressure to protect the the boiler from damage when the water pressure reaches to 0 3 Mpa Temperature extremes protection The boiler will terminate the working program when overheated...

Page 5: ...ing water temperature F 194 194 194 Adjustment range of heating water temperature F 86 176 86 176 86 176 Rated electric power W 125 125 125 Electrical protection IP X4D X4D X4D Expansion tank volume L...

Page 6: ...3 LPG PSI 0 4 0 4 0 4 Artificial Coal Gas PSI 0 15 0 15 0 15 CONNECTION PIPE DOMESTIC HOT WATER DOMESTIC HOT WATER SYSTEM 1 2 1 2 1 2 Model MGBWA070 MGBWA090 MGBWA0100 Max working pressure PSI 100 10...

Page 7: ...Fan 11 Smoke sampling 12 Air sampling 13 Flow limited loop 14 Valve of air pressure difference 15 Heating water temperature sensor 16 Limited temperature sensor 17 Expansion tank 18 Automatic air ven...

Page 8: ...ump Inside Structure of Boiler 1 Hot water temperature 2 Cold water inlet 3 Automatic bypass valve 4 Electromagnetism three way valve 5 Plate heat exchanger 6 Heating water temperature sensor 7 Gas va...

Page 9: ...damage of freezing The boiler should be connected with the heating system including a gas pipeline and an outlet Boiler and burnet must be installed and serviced only by qualified heating installer s...

Page 10: ...ter pressure detection system which may result in the lace water protection system running Refill the water until the pressure reaches to 0 1 0 12Mpa 1 1 2 bar Turn the reset button restart until the...

Page 11: ...er display within 10 minutes Check if the gas type is in accordance with the required ones Check the connecting L N polarity and grounding when connected to the 110V 60Hz power supply Ignite the gas a...

Page 12: ......

Page 13: ......

Page 14: ...ion 8 Temperature display and malfunction code display 9 Over heat problem display 10 Summar 11 Winter 12 Heating mode 13 Normal flame indication 14 DHW mode 15 Antifreezing 16 System water pressure i...

Page 15: ......

Page 16: ...ner Maybe the fan has started but the point of the air pressure sensor hasn t changed It need examination The inlet exhaust gas pipe is too long that has exceed the size permision The inlet exhaust ga...

Page 17: ...MGBWA100N11LA...

Page 18: ...with good ventilation For natural gas and LPG users D15 gas pipe can be used However we advise you use D20 pipe the reducer pipe connecting with the gas meter should less than D15 Keep a stable volta...

Page 19: ...Adjust it level with a gradienter The Connection of water system Attention The min space should be allowed for the maintenance purpose as shown on the right picture A Min45mm 55 55 50 148 Affusion Re...

Page 20: ...it goes through shall not be filled with hard articles such as cement which makes it inconvenient for maintenance The outlet and inlet of flue gas pipe shall be extended to the outside wall and shall...

Page 21: ...nnect the extended flue gas pipes with the elbow and the standard pipe Pay attention to the air tightness of the flue gas pipes While installing the elbow union please make sure that its inner pipe is...

Page 22: ......

Page 23: ...anitary hot water equipment and pipe The boiler is connected with sanitary equipment by pipe As the picture 3 4 When turning on the hot water tap the water goes through the boiler the sanitary hot wat...

Page 24: ...n the temperature in the tank reaches the set temperature the termperature sensor give the signal to the pump which will stop working The stable water temperature can be kept and ensure the realtime s...

Page 25: ...Klimaire Products Inc 7909 NW 54th Street Mimai FL 33166 Ph 305 5938358 Fax 305 5938212 www Klimaire com...

Reviews: