background image

You should keep all the parts of the boiler running 

and the power supply on Sumer/winter 

button.When the water temperature is below 8 

centigrade,the burner and pump will start until the 

temperature rises to 30 centigrade.To avoid the 

boiler keep running around the clock, or laying 

idle,please exhaust the air or add anti-freezing. 

Exhaust the water in the pipeline of heating 

system.Refilling water disposed,which can reduce 

the water hardness and avoid the sediment 

incrustration.

Use web and neutral soap to clean the boiler 

shell.  Never use abrasive detergent and 

putty-powder.

Please follow the below instruction

Check     the     air-tightness.First     check     the

air-tightness when the gas valve is closed,then

open it, here should no gas through on the timer

display within 10 minutes

Check if the gas type is in accordance with the

required ones.

Check the connecting,L-N polarity and grounding

when connected to the 110V/60Hz power supply.

Ignite the gas and check the ignition.

Check the dates of Max. Gas flow,medium Gas

flow and Min. Gas flow and relative air pressure

to see if it's accordance with listed dates.

Check the intervening progress and intervening

time of safety equipment when there is no gas

supply.

Check the switches in and outside or control

display.

Check if there is any jam in the air inlet and outlet.

Seal    the    adjustment    equipment    of    gas

valve(when the adjustment is finished).

Check the water flow of domestic hot water.

Check the airproof of all water pipe.

Check the ventilation of the installation place to

make sure it can satify the requirement.

Caution:

You can only use the boiler when the check is 

accomplished, f any of the item above cannot be 

matched,please call the technician.

Summary of Contents for Volcan MGBWA0100

Page 1: ...MGBWA070 MGBWA090 MGBWA0100 Volcan Series...

Page 2: ...e must be airproofing only gas pipe installation qualified company can do it 2 If there is any defect in the installation of exhausted air discharging system it will be possible for the exhaust regorg...

Page 3: ...n 07 water filling 08 Affusion and Drainage 08 Circuit digram of boiler 10 User manual 11 13 Malfunction display and solutions 14 For Installation and maintenance 15 22 Unpacking Inspection and Accept...

Page 4: ...cally to release pressure to protect the the boiler from damage when the water pressure reaches to 0 3 Mpa Temperature extremes protection The boiler will terminate the working program when overheated...

Page 5: ...ing water temperature F 194 194 194 Adjustment range of heating water temperature F 86 176 86 176 86 176 Rated electric power W 125 125 125 Electrical protection IP X4D X4D X4D Expansion tank volume L...

Page 6: ...3 LPG PSI 0 4 0 4 0 4 Artificial Coal Gas PSI 0 15 0 15 0 15 CONNECTION PIPE DOMESTIC HOT WATER DOMESTIC HOT WATER SYSTEM 1 2 1 2 1 2 Model MGBWA070 MGBWA090 MGBWA0100 Max working pressure PSI 100 10...

Page 7: ...Fan 11 Smoke sampling 12 Air sampling 13 Flow limited loop 14 Valve of air pressure difference 15 Heating water temperature sensor 16 Limited temperature sensor 17 Expansion tank 18 Automatic air ven...

Page 8: ...ump Inside Structure of Boiler 1 Hot water temperature 2 Cold water inlet 3 Automatic bypass valve 4 Electromagnetism three way valve 5 Plate heat exchanger 6 Heating water temperature sensor 7 Gas va...

Page 9: ...damage of freezing The boiler should be connected with the heating system including a gas pipeline and an outlet Boiler and burnet must be installed and serviced only by qualified heating installer s...

Page 10: ...ter pressure detection system which may result in the lace water protection system running Refill the water until the pressure reaches to 0 1 0 12Mpa 1 1 2 bar Turn the reset button restart until the...

Page 11: ...er display within 10 minutes Check if the gas type is in accordance with the required ones Check the connecting L N polarity and grounding when connected to the 110V 60Hz power supply Ignite the gas a...

Page 12: ......

Page 13: ......

Page 14: ...ion 8 Temperature display and malfunction code display 9 Over heat problem display 10 Summar 11 Winter 12 Heating mode 13 Normal flame indication 14 DHW mode 15 Antifreezing 16 System water pressure i...

Page 15: ......

Page 16: ...ner Maybe the fan has started but the point of the air pressure sensor hasn t changed It need examination The inlet exhaust gas pipe is too long that has exceed the size permision The inlet exhaust ga...

Page 17: ...MGBWA100N11LA...

Page 18: ...with good ventilation For natural gas and LPG users D15 gas pipe can be used However we advise you use D20 pipe the reducer pipe connecting with the gas meter should less than D15 Keep a stable volta...

Page 19: ...Adjust it level with a gradienter The Connection of water system Attention The min space should be allowed for the maintenance purpose as shown on the right picture A Min45mm 55 55 50 148 Affusion Re...

Page 20: ...it goes through shall not be filled with hard articles such as cement which makes it inconvenient for maintenance The outlet and inlet of flue gas pipe shall be extended to the outside wall and shall...

Page 21: ...nnect the extended flue gas pipes with the elbow and the standard pipe Pay attention to the air tightness of the flue gas pipes While installing the elbow union please make sure that its inner pipe is...

Page 22: ......

Page 23: ...anitary hot water equipment and pipe The boiler is connected with sanitary equipment by pipe As the picture 3 4 When turning on the hot water tap the water goes through the boiler the sanitary hot wat...

Page 24: ...n the temperature in the tank reaches the set temperature the termperature sensor give the signal to the pump which will stop working The stable water temperature can be kept and ensure the realtime s...

Page 25: ...Klimaire Products Inc 7909 NW 54th Street Mimai FL 33166 Ph 305 5938358 Fax 305 5938212 www Klimaire com...

Reviews: