10
ENGLISH
Notes
:
The continuous operation time of the unit is no
more than 35 minutes.
To refill the water tank (5) switch the unit off by
setting the on/off button (8) to the “O” position
and unplug the unit.
CLEANING AND CARE
•
Periodically wipe down the unit body and the
sprayer with a damp cloth (only after it has
cooled completely).
•
Wash the brush attachment (9) under water jet
having preliminary removed the brush from the
sprayer (1).
Attention! Do not wash the sprayer (1) under
water jet.
•
Do not use abrasives and solvents.
Scale removing
•
Pour 1 liter of water mixed with 2 tea spoons of
citric acid into the water tank (5).
•
Switch the unit on by setting the on/off button
(8) to the «I» position.
•
Let the unit operate for 5-10 minutes.
•
Switch the unit off by setting the on/off but-
ton (8) to the “O” position and leave the
steamer overnight (approximately 8 hours).
In the morning pour out the remaining liquid
from the water tank (5) and the steam cham-
ber (12) by turning the steamer upside down.
Rinse it under running water, pour 1 liter
of pure water and let the unit work until the
steam release will stop completely.
•
You can use special detergents for steam gen-
erators and garment steamers to remove scale.
STORAGE
•
Unplug the unit and wait till it cools down com-
pletely.
•
Remove the steam hose (2) by turning the
clamp (4) counterclockwise till bumping and
pulling it upwards.
•
Pour the water from the water tank (5) and
the steam chamber (12), turning the garment
steamer upside down, and dry them.
Note: For easy storing you can fix the sprayer (1)
on the steamer holder (7) with the hanger (13).
•
Keep the unit away from children in a dry cool
place.
TRANSPORTATION AT
LOW TEMPERATURES
•
If it is necessary to transport the unit at low tem-
peratures pour out water from the water tank
(5) and the steam chamber (12) by turning the
steamer upside down, and dry them.
•
Switch the unit on by setting the on/off button
(8) to the «I» position and let the unit work with
the empty water tank (5) for several minutes
until steam release stops.
PROBLEM
POSSIBLE REASON
SOLUTION
The unit does not generate
steam. The on/off button
illumination doesn’t glow.
The unit is not connected
to the mains.
Connect the unit to the mains.
The unit does not generate
steam. The on/off button
illumination glows.
Mineral deposits in the unit.
Remove the scale from the steam
chamber (12).
Water tank (5) is empty.
Fill the water tank (5) with water (the
water level should not exceed the
«MAX» mark).
The unit makes gurgling
sounds.
Steam has condensed in the
hose.
Lift the sprayer (1) vertically to
straighten the steam hose (2). In this
position the condensed water will
pour back to the steam chamber.
Irregular steam supply.
Mineral deposits in the unit.
Short stop of steam supply is not a
malfunction. If steam is not released
for a long time, remove the scale from
the steam chamber (12).
MW-3715.indd 10
23.09.2015 17:29:21